6.7 Image Calibration
When the device is installed on the day light sight as an infrared extension component,
if the reticle of white light sight is not in the center of infrared image, the image
calibration function can be used to shift the infrared image to ensure the position
consistency between the white light image and infrared image.
Fig. 6-3 Image calibration interface
Operation:
➢
Please calibrate the day light sight before mounting Clip CH50 V2.
➢
Installing Clip CH50 V2 on the day light sight and repeat the calibration steps above.
Then aiming at the target at 100 meters and shoot. Measure the horizontal distance
and vertical distance between the bullet hitting point and the aiming point
afterwards.
➢
In normal display mode, press and hold down
M (5)
button to enter the image
calibration interface. Pressing
P (4)
button or
C (6)
button briefly to move the
position of infrared image and long press to achieve quick shift. Pressing
M (5)
button to switch the orientation of X-axis (left-right) and Y-axis (up-down) while
the moving distance is displayed synchronously above the icon. (as shown in figure
6-3)
➢
When the calibration is done, long press
M (5)
button to save and exit the calibration
interface.