40 

After all settings finished, click

 “

Save” button to display OSD on the video. 

To cancel OSD, set it to “Off” and then click the button “Save”. 

 

See the figure for OSD Mode 2: 

 

Figure 4-29 OSD Mode 2 

Only if Text 1, Text 2 and Date OSD are set to “On”, you can set the text 
content and the display position of text and date.   
Context: Enter the text content in the box of Context. Text 2 supports five-row 
display and each row allows up to 40 characters (lower/upper case letters and 

0~9

).  

X-axis &Y-axis: The title axis location. Both X-axis and Y-axis can be any of 
whole numbers from 0 to 99. 
Font Size: Set the font size to be displayed. The bigger the value is, the larger 
the font size is. Default as: 3.   
After all settings finished, click

 “

Save” button to display OSD on the video. 

To cancel OSD, set it to “Off” and then click the button “Save”. 

 

 

Содержание V6202-T00 Series

Страница 1: ...INSTRUCTION MANUAL V6202 T00 V6202 T02 Series HD 1MP and 2MP Low Light IP Camera ...

Страница 2: ...ration is subject to the following two conditions This device will not cause harmful interference This device must accept any interference received including interference that may cause undesired operations The V6202 T00 V6202 T02 series HD 1MP and 2MP low light IP cameras have been tested and found to comply with the limits for a Class A digital device pursuant to the FCC rules With these rules a...

Страница 3: ...commended by manufacturer Position power source and related wires to assure to be kept away from ground and entrance Refer to qualified personnel for all service matters Save product packaging to ensure availability of proper shipping containers for future transportation Indicate that the un insulated components within the product may carry a voltage harmful to humans Indicate operations that shou...

Страница 4: ...n of Camera 8 Chapter III IE Browser Settings 10 3 1 Equipment Connection 10 3 2 Software Installation 10 Chapter IV Basic Function Operation 13 4 1 Live View 13 4 2 System 16 4 3 Network Settings 22 4 4 Camera Settings 31 4 5 Audio Video Settings 36 4 6 PTZ Functions 45 4 7 Alarm Settings 46 4 8 Record Management 48 4 9 Account Settings 51 4 10 System Log 54 Appendix I Magnetic Ring Filter Instru...

Страница 5: ... T series is bound to enhance security and convenience for your CCTV surveillance system V6202 T series is widely used in public security subways governments schools airports factories hotels museums city streets and other high resolution surveillance applications 1 2 Product Features Infinova s V6202 T00 V6202 T02 series camera has the following features and functions 1 3 progressive scan CMOS se...

Страница 6: ...aneous multi user access and parameter configuration via Web Server Compatible with Infinova s V2216 and other digital video surveillance software Provides standard SDK easily incorporated with other video surveillance software Supports public access With analog video debugging interface 1 3 System Requirement Configuration of the computer to display image and control the camera CPU Intel Pentium ...

Страница 7: ...iven Day Night Functionality ICR Sensitivity Color mode 0 01 lux F1 2 30IRE AGC ON B W mode 0 001 lux F1 2 30IRE AGC ON for V6202 T00 series Color mode 0 05 lux F1 2 30IRE AGC ON B W mode 0 01 lux F1 2 30IRE AGC ON for V6202 T02 series Exposure Scene mode Manual mode Shutter priority mode Shutter Auto Manual 1 25s 1 8000s White Balance Auto Manual Incandescent light Cool white fluorescent light Su...

Страница 8: ...ble SD Card Storage Available up to 32G Upgrade Online Available Password Protection Available Network Port One RJ45 10 100M self adaptive Ethernet port Applicable Protocols IPv4 IPv6 TCP UDP IGMP DHCP FTP SNMP V3 SMTP NTP RTP RTSP RTCP HTTP HTTPS TSL SSL 802 1X QoS PPPoE DNS ARP ICMP UPNP DDNS Profile S Alarm 2 alarm inputs 1 relay output Power Supply PoE IEEE 802 3af Class 2 12VDC 24VAC Power Co...

Страница 9: ...ise you cannot visit the camera 3 If the purchased IP camera utilizes PoE power supply please connect equipments according to the parameter of the Power Supply Switcher strictly Furthermore practical test of maximum network cable length for the Power Supply Switcher must be performed so as to avoid the camera failure caused by insufficient power supply of the Power Supply Switcher or to avoid the ...

Страница 10: ... with auxiliary illumination device in case of low illumination to avoid poor image quality 2 2 Back Panel and Control Parts 1 2 3 4 5 6 7 VIDEO OUT RESET NETWORK 802 3 af PoE 3 5 7 1 9 6 8 4 2 10 STATUS SD STATIC IP DHCP 3 1 AUDIO IN AUDIO IN GND 5 7 ALARM IN 1 ALARM IN 2 4 ALARM OUT COM 8 6 ALARM OUT 2 AUDIO OUT AUDIO OUT GND 24VAC 12VDC 10 9 TX TX RX RX RS485 NETWORK 8 9 Figure 2 1 Back View In...

Страница 11: ...VIDEO DRIVE The factory default setting is DC DRIVE 1 2 3 4 Figure 2 2 Reset Button The camera supports short press and extended press reset modes If press and hold the button from 2s to 15s i e short press Power LED Indicator will turn green and camera s parameters will restore the default values If press and hold the button more than 15s i e extended press Power LED Indicator will turn orange an...

Страница 12: ...e 2 3 2 4 Installation of Camera When mounting the camera on fixer pan tilt etc use 1 4 20UNC screw and the camera mounting screw hole located on the camera mounting bracket The camera mounting bracket can be mounted on the top or at the bottom of the camera See the figure below ...

Страница 13: ... unit to the wall or ceiling You should not engage in the installation work yourself Ask a professional to do the job since the fall of the unit can result in injuries and accidents When installing the unit on a fixer turn table etc make sure to install it firmly using a mounting hole provided on the mounting bracket to prevent fall As a failsafe against falling attach the unit by chain wire cable...

Страница 14: ... procedures of V6202 T00 V6202 T02 series camera image software are listed as follows 1 Login First start IE browser and enter IP address Enter user name and password in the pop up login interface The default IP address is http 192 168 1 100 the default subnet mask is 255 255 255 0 and the default gateway IP address is 192 168 1 254 For normal access correctly set local IP parameters before system...

Страница 15: ...ll come out in the page after a successful login Right click Add on Disabled and select Run Add on Figure 3 2 Then the prompt of security warning will pop up to remind the user to install InfiPlayerAX control Click Install Figure 3 3 After InfiPlayerAX control is installed you can view the live video If it pops up reboot prompt please cancel reboot Then close all the IE window and install InfiPlay...

Страница 16: ...m the drop down menu 2 Select Security in the pop up Internet options 3 Click Internet icon and then click Custom Level 4 Select Enable or Prompt in the options of Download unsigned ActiveX controls 5 Click Privacy in the Internet clear Block pop ups then redraw the screen and install control as per the prompt The live video will display By now the IE browser setting for image viewing comes to an ...

Страница 17: ...255 0 and the default gateway IP address is 192 168 1 254 For normal access please correctly set local IP parameters before system login The login interface is displayed as shown in figure below in English operating system Figure 4 1 User Login Do log in the system with the default super user for the first time to run the software The system default Super User is admin password admin Input the cor...

Страница 18: ... list of stream type In the H 264 major or minor stream type users can do recording snap shooting and audio in out settings Over browsing videos users can also select a proper video scale Play mode live or fluid for option Click the button to snapshoot and to enter the storage path Default C InfiPlayerAX Picture V6202 T00 V6202 T02 series supports local recording Click the recording button to star...

Страница 19: ... enable them and then the buttons will be shown as Note only when motion detection or privacy mask is enabled you can set the corresponding function in Audio Video Settings refer to Section 4 5 3 or 4 5 4 for details PTZ control and PTZ funciton When the camera is working with Pan Tilt it is able to control the PTZ to perform such operations such as direction control focus and zoom adjustment and ...

Страница 20: ...arm Settings Record setting Account Settings Add Delete User Change Password Log etc Note The following instructions are used for the super user 4 2 System Click the navigation bar System and it displays the following three option tabs System Time and Advanced as shown in Figure 4 3 4 2 1 System Information The initial interface of System Settings displays related system information such as basic ...

Страница 21: ... There are 33 time zones for your selection If Daylight Saving Time is applied in your region please turn on Daylight saving time After settings completed please click the button Save NTP Settings Set the NTP server s IP address test NTP server s status and set parameters of Sync with NTP including enable disable Sync with NTP Sync time and Sync interval ...

Страница 22: ... 4 2 3 Advanced Settings Figure 4 5 Advanced Settings Software Update Free software update is provided for V6202 T00 V6202 T02 series camera and this update service can reduce system maintenance budget Confirm the requirement submitted by user we will provide the latest software for download and help user to update the V6202 T00 V6202 T02 series camera Follow the steps below to update software Cli...

Страница 23: ...ftware Update box After that click Submit button to update software the following information will appear Figure 4 7 Click Yes button run the program to finish the update The response time is due to the program type You may wait a long time for some program Do not power off during the update process Power off will ...

Страница 24: ... the system will pop up a message as below Figure 4 8 Click OK all the parameters excluding IP address will be reset to the factory default settings If Keep current IP unchanged is unselected the IP address will be reset to the factory default settings There is time prompt in the web page during reset After reset it will skip to new web page If current IP unchanged you can access web page directly...

Страница 25: ...t subnet mask is 255 255 255 0 3 Do not power off during reset or else the reset will fail Online Reboot Click Reboot button the dialog box This operation will take 75 seconds are you sure to continue pop up Click OK and the system will restart There is time prompt in the web page during reboot After reboot it will skip to new web page Note Available only for the super user ...

Страница 26: ...ing interface will display Figure 4 9 Network Settings 11 options tabs are available Network FTP SMTP HTTPS 802 1X QOS IGMP SIP MDA DDNS and UPnP 4 3 1 Network Settings IP mode support both IPv4 and IPv6 modes Network parameters are slightly different under different IP modes ...

Страница 27: ...er the network settings completed Users can also enable disable PPPoE in this interface If enabled users can set the user name and password V6202 T00 V6202 T02 series camera supports heartbeat function In SNMP settings set and save the heartbeat sever IP address and Heartbeat interval and then the heartbeat package will be sent to the server or client which greatly facilitates the server or client...

Страница 28: ... name and password in the FTP settings and activate FTP handling way in alarm settings then alarm triggered images FTP upload can be achieved 4 3 3 SMTP Settings Figure 4 12 SMTP Settings User needs to set mail server recipient etc in SMTP settings interface Server IP Set mail server address From Set sender s mail address To Mail address of recipient CC Mail address of the person copy to ...

Страница 29: ...r s password Note there is no limit for Sender s name and password settings After setting click Set Save to take effect If user selects mail in Alarm Settings interface system will send mails according to SMTP settings 4 3 4 HTTPS Settings Figure 4 13 HTTPS Settings V6202 T00 V6202 T02 series camera supports HTTPS protocol You can import the CA certificate in the interface 4 3 5 802 1X Settings Fi...

Страница 30: ...on when needed Then select an EAP method and enter the user name and password 4 3 6 QOS Settings Figure 4 15 QOS Settings There are 4 network Qos modes to be selected 1 Normal Service 2 Max Reliability 3 Max Throughput 4 Min Delay Recommend Normal Service 4 3 7 IGMP Settings Figure 4 16 IGMP Settings ...

Страница 31: ...ngs SIP Server to configure SIP server for device SIP Server IP the IP address of SIP server Port the port number of SIP server Server ID the ID of SIP server Device ID the device ID used for registration with SIP server Alarm ID the ID registered for device alarm Register Interval the interval for re registration of device in seconds Heat Beat Interval the interval to send heatbeat information by...

Страница 32: ...ise to two places of decimal Latitude the latitude of mounting position as precise to two places of decimal 4 3 9 MDA Settings Figure 4 18 MDA Settings In MDA settings interface you can set the Sever which the motion detection alarm uploads to State disable or enable motion detection alarm upload When it s on you can set camera name user name password server IP and Port number After setting comple...

Страница 33: ...ernet to run the dynamic domain name server Operation select DDNS type in Enable option enter the IP address of the DDNS server into the address bar configure domain name user name password and update time and then save the settings Open the IE browser and enter the domain name to go to the query page of the device 4 3 11 UPnP Settings Create mapping between private network and the Internet via UP...

Страница 34: ...30 Figure 4 20 UPnP Settings In Operation column means to delete means to edit user information Click Add button to add the mapping Figure 4 21 ...

Страница 35: ...ngs 4 4 1 Basic Settings You can set the following parameters Flicker frequency 50Hz or 60Hz CVBS It automatically changes with the flicker frequency Notes analog videos are shut off after MJPEG stream is enabled To enable analog videos please disable MJPEG stream Enable or disable backlight compensation or digital WDR ...

Страница 36: ...e AGC auto aperture ICR control ICR switch time shutter speed and manual AGC can also be set in this interface Exposure Set Manual Scene and Shutter priority In the Scene mode indoor or outdoor can be selected and AGC can be set maximum 64X if set to manual mode shutter speed can be set from 1 25s to 1 8000s and manual AGC can be set to 1X to 64X yet the scene and AGC are nonadjustable if set to s...

Страница 37: ...ode videos are in color mode in Night mode videos are in black white mode in IO input 1 or 2 mode ICR is controlled by external signals AE target set AE target level It can adjust video brightness via AE target setup 4 4 3 Effect Settings In the Effect Settings interface users can adjust the brightness sharpness hue contrast saturation and 3D denoise in two ways General or Mode as shown in the fig...

Страница 38: ... save Name ICR control mode and Scene parameters for each mode Click Factoryset to restore it to default settings The camera provides 7 Scene modes Normal Anti Fog Motion Entrance Natrium Sharpen USrMode Each mode matches with a group of parameters such as brightness sharpness hue contrast saturation and 3D denoise In the Mode call users can set effect mode call status and call period ...

Страница 39: ...white balance modes including Auto Manual Incandescent light Cool white fluorescent light Sun light Cloudy and Natrium light If set to manual mode you can set the red gain and blue gain 4 4 5 Reset In the interface you can restore all the camera parameters to the factory default settings ...

Страница 40: ...5 1 Video Settings Users can set the video parameters in the format of H 264 major or minor stream and MJPEG stream such as resolution frame rate and IP rate Resolution For H 264 major stream the resolution of V6202 T02 series comes up to 1920 1080 with 1280 1024 1280 960 1280 720 1024 768 800 600 optional while the resolution of V6202 T00 series comes up to 1280 720 with 1024 768 and 800 600 opti...

Страница 41: ...frame rate for MJPEG is 10fps Note the video settings of H 264 major minor stream are linkage with that of MJPEG stream If H 264 major stream is set to 1080P 30fps minor stream closed MJPEG is only able to set to1080P 4fps If H 264 major stream is set to 1080P 25fps minor stream closed MJPEG frame is able to set to 10fps Do operate according to the prompt on the page GOV number GOV number means th...

Страница 42: ...ge is transmitted under a constant bandwidth Bit Rate Upper Limit You have to set the upper limit of bit rate if vbr is selected the stream size will be fixed if cbr is selected and the stream size is defined in the Bit Rate Upper Limit For major stream the bit rate upper limit can be 1000kbps 10000kbps for minor stream the bit rate upper limit can be 256Kbps 2000Kbps Image Quality it can be set u...

Страница 43: ... set to On you can set the text content and the display position of text and date Context Enter the text content in the box of Context which allows up to 40 characters lower upper case letters and 0 9 X axis Y axis The title axis location Both X axis and Y axis can be any of whole numbers from 0 to 99 Font Size Set the font size to be displayed The bigger the value is the larger the font size is D...

Страница 44: ...ate Context Enter the text content in the box of Context Text 2 supports five row display and each row allows up to 40 characters lower upper case letters and 0 9 X axis Y axis The title axis location Both X axis and Y axis can be any of whole numbers from 0 to 99 Font Size Set the font size to be displayed The bigger the value is the larger the font size is Default as 3 After all settings finishe...

Страница 45: ...cy Mask setting to avoid operators observing certain sensitive locations on monitor Note do turn on privacy mask function in Live View interface before privacy mask setting see Section 4 1 Figure 4 30 Privacy Mask Settings How to set the privacy masks Tick the box of motion detection area number Click the button Draw with the mouse press the left mouse button and drag on the video till a blue fram...

Страница 46: ...tection Settings V6202 T00 V6202 T02 series camera support motion detection Users can easily set the motion detection areas up to 4 with the mouse Note do turn on motion detection function in Live View interface before motion detection setting see Section 4 1 Tick the box of Zone number to be set If the motion detection area has been set a blue frame will be displayed on the screen ...

Страница 47: ...frame changes into green which indicates a successful setting Besides you can set the area name and sensitivity To cancel a motion detection area just cancel the box ticking 4 5 5 Shelter Alarm Figure 4 32 V6202 T00 V6202 T02 series camera supports shelter alarm function Users can easily set the shelter alarm areas with the mouse At first enable shelter alarm Click the button Draw with the mouse p...

Страница 48: ...k Configure Figure 4 33 For each stream the total of 90 port and RTSP port is 5 In this interface you can set the video numbers of 90 port and RTSP port The default setting is visit 2 ch major stream 2 ch minor stream and 2 ch MJPEG video via 90 port and visit 3 ch major stream 3 ch minor stream and 3 ch MJPEG video via RTSP port 4 5 7 Storage Path You can set the photo saving path and recording s...

Страница 49: ...avi To change the saving path click the button Browse and select the path from the popup dialog box 4 5 8 Audio Settings Figure 4 35 Audio Settings Sample Rate 8K Format G 711 U 4 6 PTZ Functions Figure 4 36 When the camera is working with Pan Tilt you can set camera address baud rate and protocol in the interface You can also set wiper Pan Tilt working ...

Страница 50: ...e following Alarm Settings interface Figure 4 37 Alarm Settings Alarm Configuration I O In 1 I O In 2 Settable 2 channel alarm inputs Each alarm input has 2 modes Grounded Circuit or Open Circuit Alarmout Contact used to set sending way of alarm Local Contact I O out is triggered by I O alarm in motion detection alarm ...

Страница 51: ... set the relevant alarm response ways for I O alarm in motion detection alarm shelter alarm SD card out network link down or IP address conflict Alarm out 1 if Net Contact is selected Alarm output 1 on the web page is unavailable SD card Mail FTP or Audio After setting completed click Save button to take effect Note when FTP or Mail is selected you need to set FTP or SMTP parameters in Network Set...

Страница 52: ...ard when full Overwrite or Stop Overwrite means newly recorded videos automatically overwrite the previous videos when the SD card is full Stop means recording stops when the SD card is full Recording mode Alarm triggered Always Close If alarm Triggered is selected also with SD card selected under alarm out contact in the alarm interface refer to 4 7 recording is automatically triggered when alarm...

Страница 53: ...4 8 2 Replay Figure 4 39 Replay Video Search set the start and end time and then click the search button All videos recorded during this period of time will display in the list Figure 4 40 Searching Videos ...

Страница 54: ...ht of video window the right window will disappear show as below Figure 4 41 Click the button the interface will return to the page as Figure 4 36 Download You can download the videos stored in the SD card to your PC Select the file from the video list also you can select multiple files simultaneously using the key Ctrl or Shift and then click the button Download to enter the downloading interface...

Страница 55: ...to enter download content 4 9 Account Settings The default super user is admin password admin Super user can add delete common user and change the password of common users Super user cannot change his own password A maximum of 7 common users are supported Detailed instruction about how to add and delete user are addressed below Click the Account option tab in the Settings interface the following a...

Страница 56: ...o special character is allowed The string length of user name is legal between 1 and 30 characters and that of password is between 5 and 20 characters 3 Click OK button If the setting is successful the new user name will appear in the account list Take new user user1 as an example Figure 4 45 2 Delete Users In the Account setting interface click button of the Operation item to delete user The foll...

Страница 57: ...t would be automatically updated 3 User Password Change Click button in the account list the dialog box of Edit User Information will pop up Figure 4 47 Input the old password enter the desired new password for twice and then click OK button the following picture will appear Figure 4 48 ...

Страница 58: ...d log information will appear on the right of the screen Figure 4 49 It can display 30 logs on a page The user can turn over the pages or skip to the desired page by clicking the below arrows Click Delete logs a prompt will come out Then click Yes to clear logs ...

Страница 59: ...ring filter and lead the power cable through Step 2 Wire the power cable on the magnetic ring filter 3 rounds or more Make sure the filter can be well closed Step 3 Close the magnetic ring filter Notice The magnetic ring filter should be installed no more than 50 mm away from the power output connector As shown in Figure 3 the cable length from A to B should be 50mm at most Figure 1 Closed magneti...

Страница 60: ...upply Switcher insufficient Shorten the length of the power supply network cable or replace Power Supply Switcher of larger power The network camera does not perform initiation after power on If PoE power supply is used connection to other electric appliance make the ground level not in the correct level Disconnect other electrical appliance The plug in for viewing image is installed incorrectly R...

Страница 61: ...ameter shall be 0 8000mm A lower diameter value tends to cause voltage loss and even system instability 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 362 110 60 47 14 75 22 119 36 301 91 70 40 12 64 19 102 31 258 78 80 35 10 56 17 89 27 226 68 90 31 9 50 15 79 24 201 6...

Страница 62: ...e Use shielded cables or thread the cables through metal tubes for burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to...

Страница 63: ...Infinova 51 Stouts Lane Monmouth Junction NJ 08852 U S A Tel 1 888 685 2002 USA only 1 732 355 9100 Fax 1 732 355 9101 sales infinova com V2 3 1409 ...