Infinova V2923ACN Series Скачать руководство пользователя страница 47

41 

 

Appendix I System Alarm Programming 

Program the system alarm in 1.5 menu SET ALARM. Please follow 
the steps below to program the V2923ACN system alarm: 
1.

 

Monitor arm types programming; 

2.

 

Alarm Contact/Camera programming; 

3.

 

Alarm Contact/Monitor programming; 

4.

 

Alarm title programming. 

 

Monitor Arm Types Programming 

PREVIOUS MENU

SET ALARM

1 SET MONITOR ARM TYPES
2 SET ALARM CONTACTS
3 SET MONITOR CONTACTS
4 SET ALARM TITLE

PREVIOUS MENU

SET MONITOR ARM TYPE

MON  ARM TYPE  ACK
0001   DIS  ---           N
0002   DIS  ---           N
0003   DIS  ---           N
0004   DIS  ---           N
0005   DIS  ---           N
0006   DIS  ---           N
0007   DIS  ---           N
0008   DIS  ---           N

 

 
Select SET MONITOR ARM TYPES from SET ALARM to 
program monitor arm type. 
To arm a monitor, 
1.

 

Move the cursor to the ARM TYPE entry corresponding to the 
monitor to be armed. 

2.

 

Enter the desired arm type code, or press ACK key to select in 
sequence. 

3.

 

Press ACK key to confirm. The selected arm type will be 
displayed in the entry. 

 

Alarm Contact/Camera Programming 

PREVIOUS MENU

SET ALARM

1 SET MONITOR ARM TYPES
2 SET ALARM CONTACTS
3 SET MONITOR CONTACTS
4 SET ALARM TITLE

PREVIOUS MENU

ALARM CONTACT SETUP

ACN     CAM     DWL     PRE     AUX     CN
0001     0001      02        000        0-         N
0002     0002      02        000        0-         N
0003     0003      02        000        0-         N
0004     0004      02        000        0-         N
0005     0005      02        000        0-         N
0006     0006      02        000        0-         N
0007     0007      02        000        0-         N
0008     0008      02        000        0-         N

 

Select SET ALARM CONTACTS from SET ALARM to define the 
camera to be contacted upon an alarm. 
1.

 

Move the cursor to the CAM entry corresponding to the 

desired alarm contact (ACN). 

2.

 

Enter the desired Camera Number (1-1024) or Pseudo 

Number (1-9999) on the keypad. 

3.

 

Press the ACK key to confirm. The entered Camera Number 

will be displayed in the entry. 

 

Alarm Contact/Monitor Programming 

ACN      001      002     003      004

0001        N          N        N         N
0002        N          N        N         N
0003        N          N        N         N
0004        N          N        N         N
0005        N          N        N         N
0006        N          N        N         N
0007        N          N        N         N
0008        N          N        N         N

MON/CONTACT TABLE - -

MONITORS

PREVIOUS MENU

PREVIOUS MENU

SET ALARM

1 SET MONITOR ARM TYPES
2 SET ALARM CONTACTS
3 SET MONITOR CONTACTS
4 SET ALARM TITLE

 

 
Select SET MONITOR CONTACTS from SET ALARM to define 
the monitor to be contacted upon an alarm. 
1.

 

Move the cursor in the desired Monitor entry corresponding to 
the desired alarm contact (ACN). 

2.

 

Use the ACK key to toggle between "N" and "Y" (N = Disabled, 
Y = Enabled). 

3.

 

Repeat Steps 1 and 2 until all the desired entries are defined. 

4.

 

Move the cursor to the PREVIOUS MENU line, and press the 
ACK key to return to the SET ALARM menu. 

 
Alarm Title Programming 

TITLE-

PREVIOUS MENU

ALARM-0001

PREVIOUS MENU

SET ALARM

1 SET MONITOR ARM TYPES
2 SET ALARM CONTACTS
3 SET MONITOR CONTACTS
4 SET ALARM TITLE

ABCDEFGHIJKLM
NOPQRSTUVWXYZ
a b c d e f g h I j k l m
n o p q r s t u v w x y z

0 1 2 3 4 5 6 7 8 9<>

: - . / ;

 

 
Select SET ALARM TITLE from SET ALARM to define a title for 
an alarm. 
1.

 

Select the number of an alarm for title programming. 

2.

 

Move the cursor to the selection area to select the desired 
character, number or symbol, and then press ACK key to confirm. 
The selected character, number or symbol will be displayed in 
the TITLE fields. 

3.

 

Repeat steps 1 and 2 until all the desired alarm is defined. 

 

Содержание V2923ACN Series

Страница 1: ...RM9 microprocessor and based on the LINUX operation system V2923ACN External CPU Module can provide automated electronic surveillance or it can allow even a single user to control an entire CCTV syste...

Страница 2: ......

Страница 3: ...rnal CPU Module complies with Part 15 of the FCC rules Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference rece...

Страница 4: ...d by manufacturer Position power source and related wires to assure they will be kept away from ground and access way Refer all service matters to qualified personnel Save product packaging to ensure...

Страница 5: ...5 2 Menu Navigation and Operation 15 5 3 System Menu 15 5 3 1 Setting Time and Date 15 5 3 2 Setting System Tours 17 5 3 3 Set System Salvos 18 5 3 4 Set Event Timer 20 5 3 5 Set Alarm 21 5 3 5 1 Set...

Страница 6: ......

Страница 7: ...amera and keyboard With User Priority system administrators can define a maximum of 64 system users and assign each user a password and a priority level Each of the 99 priority levels can also be conf...

Страница 8: ...high speed DATA LINE 5 System Priority System priority provides operators with the following detailed controls Keyboard to Monitor Set the keyboard group that can control the monitor Keyboard to Camer...

Страница 9: ...o windows optional video card E maps control menus and icons password encryption and login Convenient arming disarming V29X3SW System Setup Software Windows based Uploads and downloads the system setu...

Страница 10: ...menus 6 Power Switch and power inlet 2 2 Hardware Connection All internal switch settings on the modules should be made before system connections are started Ensure that all connections are properly...

Страница 11: ...Infinov a R 1 2 3 4 5 6 7 8 9 0 C A M NE XT R U N HO LD O F F A R M A C K O F F CL OS E OP EN NE AR F A R WI DE TE LE SH OT M O N PR OG A UX IRI S FOC US ZO OM MONIT OR CAME RA LEN S ENTE R SWITCH ER...

Страница 12: ...ge right key 30 SHOT Enter key 31 PATRN Exit key 32 Joystick LAST LOCK ACK NEXT RUN HOLD OFF ARM SALVO PATRN SHOT PROG 1 2 3 4 5 6 7 8 9 CAM 0 MON F1 CLEAR F2 CLOSE OPEN IRIS OFF ON AUXILIARY NEAR FAR...

Страница 13: ...ase refer to Chapter V Menu Programming System Set Priority and User Menu for details on password programming When a password for a user is assigned successfully the user must log on to the system bef...

Страница 14: ...le times each dwell time can be defined separately V2923ACN supports two tour kinds of tours System Tour and Monitor Tour System Tours are defined by Menu Programming see Chapter V Monitor Tours are d...

Страница 15: ...also enter 30 F2 or 33 F2 on the keyboard at PROGRAM mode connected to host matrix to download setup to non host matrix switchers Host matrix will download setup information to non host matrix switche...

Страница 16: ...The monitor used for channel application can be called up by keyboard and can be view video and contol cameras but it can not be used for switching 4 When any monitor is set as the monitor is disabled...

Страница 17: ...f shifting title position with joystick 51 F2 Disable the function the command 50 F2 activates so as to resume function of joystick to control dome camera 70 F2 Displays main procedure s version numbe...

Страница 18: ...day of the week 3 Place the key switch in OPERATE position 4 5 Setting Preset Infinova series receivers and Super Domes feature preset function programmable via the SHOT key on the keyboard Presets p...

Страница 19: ...ors 1st 2nd 3rd 4th Assuming there is a sequence of 6 received alarmed videos 5th 1st 2nd 3rd 1st 2nd 4th 1st Monitor 2nd Monitor 3rd Monitor 1st Monitor 2nd Monitor 3rd Monitor The first 3 alarmed vi...

Страница 20: ...Hold Manual Clear BHM First Monitor Arming Type Display Second Monitor Arming Type Display 13 Dual Hold and Sequence Instant Clear DHI DSI 14 Dual Hold and Sequence Auto Clear DHA DSA 15 Dual Hold an...

Страница 21: ...IRIS section OFF page backward and ON page forward in the AUXILIARY section Access a sub menu There are two ways to access a sub menu Move the cursor to the desired sub menu and press the ACK key or...

Страница 22: ...e V2923ACN displays time in a 24 hour format HH MM SS hour minute second Example To set the time to 11 48 25 1 Enter 11 on the keypad and press the ACK key 2 Enter 48 on the keypad and press the ACK k...

Страница 23: ...menu to define system tours V2923ACN provides 128 system tours each including 128 cameras with programmable Dwell Times DWL Presets PRE and Auxiliary Relays AUX A single screen page permits setup oper...

Страница 24: ...wn above indicate that each time the tour cycle processes to ENT 003 Salvo 3 will be called up for 5 seconds The monitor that runs the tour will become the first monitor for the called salvo T tour to...

Страница 25: ...salvo Item Function C CAM Refers to the camera number associated with each position monitor To select a camera 1 Enter the camera number 1 1024 for Real number or 1 9999 for Pseudo number 2 Press the...

Страница 26: ...rst event timer in the system The menu items are described below SYSTEM RETURN MAIN A 1 SET TIME AND DATE 2 SET SYSTEM TOURS 3 SET SYSTEM SALVOS 4 SET EVENT TIMERS 5 SET ALARM 6 SET SOURCE GROUPS 7 SE...

Страница 27: ...RM TITLE PREVIOUS MENU SET MONITOR ARM TYPES MON ARM TYPE ACK 0001 DIS N 0002 DIS N 0003 DIS N 0004 DIS N 0005 DIS N 0006 DIS N 0007 DIS N 0008 DIS N Among them MON selects the monitor to arm ARM TYPE...

Страница 28: ...tions discussed in Item F Item Function C DWL Defines the Dwell Time for the CAM entry To set the Dwell Time for the camera 1 Enter the Dwell Time 1 60 in seconds or enter 61 to hold the camera 2 Pres...

Страница 29: ...fine a wired group the last CN entry of the group must be set to N or S while all the previous CN entries are set as W ACN CAM DWL PRE AUX CN 0005 0005 02 01 1 ON W 0006 0006 02 01 0 W 0007 0007 02 01...

Страница 30: ...tomatically responding to the alarm contact Example To allow alarmed videos triggered by Alarm Contact 9 to be automatically switched to Monitor 5 1 Press the ON key in the AUXILIARY section to displa...

Страница 31: ...SET SOURCE GROUPS 1 SET KEYBOARD GROUPS 2 SET CAMERA GROUPS PREVIOUS MENU Of which KEYBOARD GROUPS to set the serial number for keyboard group Up to 99 keyboard groups can be set NUM serial number fo...

Страница 32: ...GE PARAMETERS Y PREVIOUS MENU A B C D E F G SET PRIORITY AND USER 1 SET PRIORITY 2 SET USER PREVIOUS MENU The SET PRIORITY menu shown above is used to configure each of the 99 priority levels Upon ini...

Страница 33: ...USER ID 00 ENABLE PRIORITY 8 PASSCODE XXXXXX C PREVIOUS MENU The SET USER menu can be used to assign a password protected user number and a priority level for each of up to 64 users Note the menu is n...

Страница 34: ...on this monitor Item Function C KEYBOARD GROUP Set the keyboard group that can control the monitor The default setting is ALL which indicates that all keyboards can control the monitor To program the...

Страница 35: ...Note the menu is not available for non host matrix switcher SET FUNCTION ENT MON USE KEYG CAMG 001 001 001 MON ALL ALL A B C D E Item Function A ENT Sequence number B MON The number of the monitor und...

Страница 36: ...sent N no video sync signal loss occurred Sample Menu MON SITE CAM ST TOUR V S 001 0015 R 001 Y Y 002 0021 H 002 Y Y MONITOR STATUS The sample menu indicates that Monitor 1 is displaying Camera 15 and...

Страница 37: ...firm Note If Camera A s Real number is chosen as the Pseudo number for Camera B Camera B s real number will then be automatically assigned as the Pseudo number for Camera A To locate a Pseudo camera n...

Страница 38: ...he current active field and the other indicating the alphanumeric characters to be selected The NEXT key is used to move the field positioning cursor and the joystick is used to move the cursor within...

Страница 39: ...ber of pseudo camera start number of second pseudo camera start number of real camera number start number of REFLAC number and press SAVE then the camera number pseudo camera second pseudo camera REFL...

Страница 40: ...l appear 5 5 6 Video Loss RETURN MAIN CAMERA PREVIOUS MENU CAMERA 0001 VIDEO LOSS OFF CONTACT ALARM 0001 A B C 1 PSEUDO 2 TITLE 3 CAMERA KEYBOARD 4 BATCH PSEUDO 5 CLEAR SETTING 6 VIDEO LOSS The VIDEO...

Страница 41: ...ilable to set this option on the main CPU of dual CPU The baud rate here is 115200 fixed 5 7 Non host matrix Configuration The V2923ACN network system is constructed in Host networking way In the netw...

Страница 42: ...e the cursor to the first entry of the item 2 Enter the first three digits of the 12 digit IP address and press the ACK key Note The first three digits various in the range of 001 223 and 127 is unava...

Страница 43: ...er Options The setting ranges from 1 to 999 seconds Item Function H V2060NET RETRANSFER During networking among V2060 matrix switcher if Y is set the switching commands sent from V400 will retransfer...

Страница 44: ...68 000 003 03 0004 192 168 000 004 03 0005 192 168 000 005 03 0006 192 168 000 006 03 0007 192 168 000 007 03 0008 192 168 000 008 03 1 LOCAL SITE NUMBER 2 VIDEO TRUNK ASSIGNMENT 3 REMOTE SITE IP ADDR...

Страница 45: ...ion of DOWNLOAD 5 8 System Backup The BACKUP menu enable user to backup all the program data in the system and to restore the backup program data or to restore the factory set Details as shown below I...

Страница 46: ...nguage English or Chinese Item Function SELECTION Selects menu language Options and code 0 English 1 Chinese To select language Enter LANGUAGE menu and the cursor will locate at the language selection...

Страница 47: ...sponding to the desired alarm contact ACN 2 Enter the desired Camera Number 1 1024 or Pseudo Number 1 9999 on the keypad 3 Press the ACK key to confirm The entered Camera Number will be displayed in t...

Страница 48: ...ost matrix switcher and SITE2 is set to be satellite matrix switcher The menu setting is shown below VIDEO TRUNK ASSIGNMENT PREVIOUS MENU OUT IN ENT SITE MON SITE CAM 0001 001 001 002 2001 0002 002 00...

Страница 49: ...igh speed data line 2 BNC connectors External sync input output BNC connectors Programming monitor BNC connector Power Supply Input Voltage 100 240VAC Power Requirements 5W Mechanical CPU Dimensions H...

Страница 50: ...44 Appendix V Typical System Application...

Страница 51: ...meter shall be 0 8000mm A lower diameter value tends to cause voltage loss and even system instability 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 9...

Страница 52: ...e Use shielded cables or thread the cables through metal tubes for burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the w...

Страница 53: ......

Страница 54: ......

Страница 55: ......

Страница 56: ...Infinova 51 Stouts Lane Monmouth Junction NJ 08852 U S A Tel 1 888 685 2002 USA only 1 732 355 9100 Fax 1 732 355 9101 sales infinova com V1 3 1611...