18
Item
Function
D
DWL
Defines the Dwell Time for the CAM entry.
To set the Dwell Time for the camera,
1)
Enter the Dwell Time (1-60) in seconds, or enter "61" to hold the tour on the camera;
2)
Press the ACK key to confirm.
Item
Function
E
PRE
Sets the camera's preset position (Preset).
To sets a preset position for the camera,
1)
Enter the preset number (1-255), or "0" to disable the Preset function;
2)
Press the ACK key to confirm.
Item
Function
F
AUX
Sets the on/off status for the camera's auxiliary relay to switch on/off automatically during the
tour.
Options and code numbers
1 = AUX 1 ON
2 = AUX 2 ON
3 = AUX 3 ON
4 = AUX 4 ON
5 = AUX 1 OFF
6 = AUX 2 OFF
7 = AUX 3 OFF
8 = No auxiliary called
Item
Function
G
CN
Connect Next (see the following examples for details).
Options
Y
= yes (to call up the next camera in the table to the next contiguous monitor).
ENT CAM DWL PRE AUX CN
001 0001 02 01 0- Y
002 0002 00 02 0- N
The sample entries shown above indicate that during the tour, when Camera 1 is called to the
monitor, Camera 2 (entry 002) will be simultaneously called to the next contiguous monitor.
Note
: The dwell time of Camera 2 is set to "0" because its dwell time is controlled by the previous
entry.
N
= no (not to use the Connect Next function).
S
= salvo (to call a system salvo for the specified dwell time). At this point, the CAM entry
refers to the salvo number.
ENT CAM DWL PRE AUX CN
003 0003 05 00 0- S
The sample entries shown above indicate that each time the tour cycle processes to ENT 003,
Salvo 3 will be called up for 5 seconds. The monitor that runs the tour will become the first
monitor for the called salvo.
T
= tour (to call another system tour). At this point, the CAM entry refers to the tour
number.
Note
that a tour cannot call itself.
ENT CAM DWL PRE AUX CN
005 0002 00 00 0- T
The sample entries (TOUR 001) shown above indicate that each time the tour cycle processes to
ENT 005, System Tour 2 will be called up to the same monitor.
Note:
The dwell time is set to "0" here because it is controlled by the dwell time specified in
System Tour 2.
To select an appropriate CN value,
1)
Use the ACK key to toggle through the options.
2)
Press the NEXT key to select the desired option.
For details on how to run a system tour, please refer to
Section 3.5
.
5.3.3 Set System Salvos
SYSTEM
RETURN MAIN
SET SYSTEM SALVOS
SALVO - 001
PREVIOUS MENU
POS
001
002
003
004
005
006
007
008
CAM
0001
0002
0003
0004
0005
0006
0007
0008
PRE
01
02
03
04
05
00
00
00
AUX
0-
2 ON
3 ON
4 ON
3 ON
0-
0-
0-
CN
Y
Y
Y
Y
Y
N
Y
N
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM
6 SET SOURCE GROUPS
7 SET PRIORITY AND USERS
V2923ACN permits up to 128 system salvos for programming. A
System Salvo is a group of cameras, with associated presets and
auxiliary actions, which can be called simultaneously to a
contiguous group of monitors.
A single screen page permits setup operations ( PRE, AUX) for 8
cameras in a system salvo. The CLOSE/OPEN keys can be used for
page-down/page-up and ON/OFF keys used for page forward and