2. Setting Communication Baud Rate&Protocol
Communication baud rate of the domes can be set via the first 2
positions of 6--position DIP Switch S1; The 3
rd
position is used
to set protocol; the 6
th
position is used to set RS485 terminal
resistor connection status; the other 2 positions are reserved Refer
to the following tables for specific setting: X indicates not
available.
Note: The 4
th
position of S1 must be set to ON.
DIP Switch S1
Baud Rate
1
2
3
4
5
6
2400 BPS
OFF
OFF
X
ON
X
X
4800 BPS
ON
OFF
X
ON
X
X
9600 BPS
OFF
ON
X
ON
X
X
IDP Self-adaptive
X
X
OFF
ON
X
X
485 Terminal
resistor
X X X
ON
X
ON
No 485 Terminal
resistor
X X X
ON
X
OFF
Appendix II Assembly and Disassembly
Procedures
Assembly Procedures
Line up the two tabs located on the upper side of the dome drive
with the corresponding grooves in the housing. Insert both tabs into
the grooves. Push up the dome insert until both tabs click into place.
Be sure that you hear two clicks.
Disassembly Procedures
Disassembly is the inverse procedure of installation. Ensure that the
disassembly must be carried out after the dome power has been turn
off.
Note:
The following instructs how to disassemble the dome drive:
Hold the dome drive at the bottom of the two tabs located on the
upper side of the dome drive. Then use your fingers to press inward
until they are divorced from the grooves in the housing. Keeping
the tabs and the grooves at this status, pull the dome drive down
slowly.