Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.
Control Modes
There are 3 modes:
●
Stand-alone
●
Master/Slave
●
DMX512 (15CH, 18CH)
One Infinity (Stand-alone)
01)
Fasten the effect light onto firm trussing. Leave at least 1 meter on all sides for air circulation.
02)
Always use a safety cable (ordercode 70140 / 70141).
03)
Plug the end of the electric mains power cord into a proper electric power supply socket.
04)
When the Infinity is not connected with a DMX cable, it functions as a stand-alone device.
05)
Please see page 20 for more information about the built-in programs.
Multiple Infinitys (Master/Slave control)
01)
Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation.
02)
Use a 3-pin/5-pin XLR cable to connect the Infinity.
The pins:
01) Earth
02) Signal -
03) Signal +
03)
Link the units as shown in fig. 08. Connect the first unit's DMX "out" socket with the second unit's "in"
socket, using a DMX signal cable. Repeat this process to link the second, third, and fourth units.
You can use the same functions on the master device as described on pages 16-22. This means that
you can set your desired operation mode on the master device and all slave devices will react the
same as the master device.
Multiple Infinitys (Master/Slave control)
Fig. 08