Attach the Zero kit front plate using the 9 x No6 screws provided. 

 

Finish the wall now to the front edge of the sides and bottom of the zero clearance box assembly using 
plasterboard and plaster skim. Please note a 26mm gap needs to be maintained between the deflector 
plate and the plaster board edge. (

Failure to maintain this gap could result in excessive settlement 

cracking

 

when the appliance is in operation

). This gap will be cover by the outer trim assembly. 

 

 

 

Содержание 890 HDBF

Страница 1: ...T This appliance is guaranteed for 12 months subject to conditions The 5 year extended parts warranty will only be valid if the annual service recommended in this manual has been completed and applian...

Страница 2: ...Bed Layout 10 Technical Specification 12 Siting the Appliance 13 Commissioning the Appliance 31 Annual Service Requirement 33 Maintenance 35 Short Spares List 40 Your Fire Years Parts Extended Warrant...

Страница 3: ...and and Wales All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued...

Страница 4: ...Consumer Protection Information As manufacturers and suppliers of heating products we take every care to ensure that the design and construction has to meet the general safety requirements when prope...

Страница 5: ...taining may appear on some parts of the fuel bed This is quite normal However if excessive black staining occurs it may be due to the fuel bed shapes laid incorrectly This should be checked prior to c...

Страница 6: ...ng displays an UNLOCK graphic Fig 2 prompting the button to be pressed simultaneously Whilst both are pressed a progress bar Fig 3 will complete If either button is released before the progress bar ha...

Страница 7: ...and hold down until the progress bar has completed If the is released before the progress bar has completed the operation will cancel Mode select With the fire running on manual operation you can acc...

Страница 8: ...y time Selecting auto control The auto function can only be selected once the appliances has been started and initiated into manual mode Once in manual mode press and release the button to enter the m...

Страница 9: ...rature display units use selector wheel to select either Celsius degree C or Fahrenheit degree F Press the button to save selection Gas fire pair code The device screen displays the current operating...

Страница 10: ...tom 5 M4 nuts but do not remove completely Remove the remaining M4 nuts and glass clamps See Fig 8 Carefully lift the glass panel from within the bottom glass clamp Remove the log and bark chip shapes...

Страница 11: ...t flame picture reduce the risk of glass staining Place a thin layer of vermiculite across the burner taking care around the pilot area Insert the front grill into the gap between the burner and front...

Страница 12: ...rglow in the area highlighted Place the four corresponding overlay shapes as shown Place the remaing six ember shapes within the inlet cover as shown 6 5 No 5 log should be located first Place a small...

Страница 13: ...alorific value of the fuel has been used for this efficiency calculation Gastec have certified the test data from which it has been calculated The efficiency value maybe used in the UK Government s St...

Страница 14: ...user Regulations All relevant parts of the local and national building regulations and all relevant recommendations of the following British standards Failure to do so could lead to prosecution The f...

Страница 15: ...th of 600mm The flue and air duct must not have any bends or joints The flue outlet must terminate on a suitable outside wall The minimum flue terminal clearances which must be maintained are as shown...

Страница 16: ...f the plaster and to achieve this larger rebated surround maybe necessary Ensure that the transit bolts are removed from the top of the firebox before installation Check with the supplier or manufactu...

Страница 17: ...n Remove the 2 off M4 x 50mm transit bolts from the top of the firebox as show above These bolts are used to secure the explosion relief flaps in transit Failure to remove them could put the user at r...

Страница 18: ...orizontally and vertically at the cross point previously marked Cut out the brickwork of the inner skin of the cavity wall for the lintel and fix the lintel Cut out the brickwork under the lintel betw...

Страница 19: ...e that it is being installed with The minimum finished height from the bottom of the trim to floor level is 187mm Slide the firebox back into the chamber and secure the firebox in place The 890 HD can...

Страница 20: ...d and finishing plaster directly around the edge of the slip plate assembly This will reduce the risk of cracking of the plaster finish around the appliance but will not remove the chance of settle cr...

Страница 21: ...nd heat resistant finishing plaster directly around the appliance Fit plaster board to the remaining chimney front If a plaster edge finish is required the fire box will need to be recessed against th...

Страница 22: ...the floor level This can be acheieved by measuring the bottom slip and hearth height less 187mm You will need to allow for the hearth bedding material Attach the slip plate assembly to the firebox usi...

Страница 23: ...sonry drill make one pilot hole completely through the wall Ensure the hole is drilled accurately at the centre and square to the wall both horizontally and vertically at the cross point previously ma...

Страница 24: ...o 2 890 HD BF INSTALLATION INSTRUCTIONS It is recommended to open out a larger area of plaster around the Zero kit outer box opening This will reduce the chance of settlement cracking during operation...

Страница 25: ...d When routing the cable consideration should be taken to avoid contact with the appliance and flue assembly Secure the Outer box assembly within the open through the fixing holes present within the l...

Страница 26: ...ox making sure the flue pipes are fully engaged with the inner and outer flue spigot connections Please refer to sections flue connect mains cable and gas connection guidance as this stage on pages 29...

Страница 27: ...ge of the sides and bottom of the zero clearance box assembly using plasterboard and plaster skim Please note a 26mm gap needs to be maintained between the deflector plate and the plaster board edge F...

Страница 28: ...7 Issue No 2 890 HD BF INSTALLATION INSTRUCTIONS Attach the top and bottom cover plates using the 8 x No6 screws provided within the kit as shown below Locate the outer trim within the internal studs...

Страница 29: ...INSTALLATION INSTRUCTIONS Position the four block magnets upon the trim top bracket and the bottom cover plate with the raised areas as shown below Locate the inner fascia below the deflector plate an...

Страница 30: ...xemption number 1 of 1996 Where the pipe enters the fire the outer sleeve must be sealed to the grommet and the pipe must be sealed to its outer sleeve using suitable mastic Power lead routing The pow...

Страница 31: ...k of the fire to the outside wall Cut the outer tube to the recorded length Add 18mm to this measurement to determine the length of the inner tube and cut to size NOTE The inner tube will be 18mm long...

Страница 32: ...lace the pressure test point screw Turn on the gas supply and check the pressure test point for soundness with detection fluid Refit the gas cover Fuel Bed Layout Fuel bed layout should be fitted usin...

Страница 33: ...P a g e 32 Issue No 2 890 HD BF INSTALLATION INSTRUCTIONS Fitting the glass fascia Using the guides shown below engage the glass fascia within the slots present within the fire box assembly...

Страница 34: ...ackup option C cell batteries not included within this appliance Demonstrate the lighting and extinguishing procedures to the user and the removal and refit of the glass panel for cleaning and the fit...

Страница 35: ...P a g e 34 Issue No 2 890 HD BF SERVICE FAULT FINDING INSTRUCTIONS...

Страница 36: ...P a g e 35 Issue No 2 890 HD BF SERVICE FAULT FINDING INSTRUCTIONS Maintenance...

Страница 37: ...P a g e 36 Issue No 2 890 HD BF SERVICE FAULT FINDING INSTRUCTIONS...

Страница 38: ...P a g e 37 Issue No 2 890 HD BF SERVICE FAULT FINDING INSTRUCTIONS...

Страница 39: ...omplete tray into the fire in reverse order and re connect all parts 13 Turn on the Gas supply check for soundness and re commission Replacement of Injector 1 Repeat operations 1 4 for removal of gas...

Страница 40: ...ss panels by removing the top bracket 3 Remove the rear glass panel 4 Remove the fixing screws and top baffle plate 5 Remove the 8 fixing screw to remove the assembly from the firebox 6 Replace both g...

Страница 41: ...letes see Fig 3 This will access the menu see Fig 4 Use the selector wheel and select the gas fire option Press simultaneously to delete the current channel The handset will re load to NO DEVICE see F...

Страница 42: ...ctly filled out and record of annual services must be up to date and supported by receipts in each case 5 This warranty is not transferable and relates to the original installation only 6 The Registra...

Страница 43: ...ed five year parts warranty and the appliance must be registered by completing and return the registration document last page of this booklet to Infinity Fires Date of first service Engineers Name Gas...

Страница 44: ...let elbow been fitted for servicing Has the gas supply been thoroughly purged prior to connection to remove any debris Has a gas tightness test been completed prior to breaking into the gas supply and...

Страница 45: ...Company name Gas safe number Date of installation Your Details Name Address Post Code Telephone No Product Details Model 890 HD BF Serial No Date of Purchase This information can be found on the label...

Страница 46: ...P a g e 45 Issue No 2...

Страница 47: ...P a g e 46 Issue No 2...

Страница 48: ...s warning label 1409 Silicone sealing strip 4818 Liners fitted sides rear top AAA Batteries x 4 Remote control handset Handset holder 7191 Glass retaining brackets fitted 8mm nut spinner 5435 Magnets...

Отзывы: