P a g e
|
41
LT7593 Issue No 1 (03/2017)
890 HD INSTALLATION INSTRUCTIONS
Run the match along the edge of the inlet air channel. All smoke must be drawn into the inlet
channel if the spillage test is satisfactory.
If spillage occurs wait a further five minutes and repeat the test.
Repeat the test with doors open and with any extractor fans in other rooms in operation.
If spillage is detected the cause must be discovered and the fault corrected. If the fault cannot
be corrected, disconnect the fire from the gas supply and seek expert advice. Spillage can be
caused by a restriction in the flue system, down draught or insufficient ventilation into the room
where the fire is installed.
Advise The Customer.
The glass front of this fire acts as a dress guard conforming to BS 1945 (1997) and satisfies the
heating appliance regulations (1991) however; a fireguard conforming to BS6539 (1997) must be
used to protect young children, the elderly, or infirm.
During initial “burn off”, an odour may be evident during the first few hours of use. This is due to
the surface coating on the metal w
ork “burning off”. The odour produced is harmless and will
disappear after a short period of time.
Any debris should be cleared from the appliance.
The appliance should be serviced annually by a Gas Safe registered engineer in accordance
with the Service instruction section.
Point out the position of the power source for the appliance, plus demonstrate using the
additional battery holder and adaptor lead, the battery backup
option. (“C” cell batteries not
included within this appliance).
Demonstrate the lighting and extinguishing procedures to the user and the removal and refit of
the glass panel for cleaning and the fitting of the battery back up kit.
Hand these instruction over to the user along with the battery holder, adaptor lead plus M4 nut
runner for the removal of the glass panel.
Please be aware that the non-reflective glass may in some lights and from some angles have a
blue tinge to it this is perfectly normal. Also be aware that if the glass liners are fitted in the fire
with the non-reflective glass you will still have a reflection in the glass liners.
Содержание 890 HD
Страница 22: ...P a g e 21 LT7593 Issue No 1 03 2017 890 HD USERS INSTRUCTIONS Place the last log as shown ...
Страница 45: ...P a g e 44 LT7593 Issue No 1 03 2017 890 HD SERVICE FAULT FINDING INSTRUCTIONS Fault Finding Charts ...
Страница 46: ...P a g e 45 LT7593 Issue No 1 03 2017 890 HD SERVICE FAULT FINDING INSTRUCTIONS ...
Страница 47: ...P a g e 46 LT7593 Issue No 1 03 2017 890 HD SERVICE FAULT FINDING INSTRUCTIONS ...
Страница 57: ...P a g e 56 LT7593 Issue No 1 03 2017 ...
Страница 58: ...P a g e 57 LT7593 Issue No 1 03 2017 ...
Страница 59: ...P a g e 58 LT7593 Issue No 1 03 2017 ...