9
User Manual — Infinea mPOS Plus
Minimize Deactivation
To minimize the potential for deactivation, follow all
storage and operating temperature guidelines. Refer to
Technical Specifications for details.
Long term storage can cause temporarily decreased
battery capacity. In order to recover maximum
performance, it may be necessary to go through several
cycles of fully charging and discharging the battery.
When storing the device for longer than three months,
the battery should be charged every three months at a
minimum to prevent leakage, reduced performance, and
potential deactivation.
Replace the Battery
The main battery can only be replaced by Infinite
Peripherals. Attempting to disassemble a SRED-
encrypted unit, renders it unusable and may void your
warranty.
Keypad and Menu Navigation
The buttons on the keypads access specific functions
and allow you to navigate through the menu options and
screens.
Note:
The keypad is ADA-compliant which means the Clear, OK, backspace,
and the number 5 keys have distinct, raised markings at the bottom
left corner of each key.
Tap the appropriate button to perform the following:
•
Power to turn on the Infinea mPOS Plus.
•
System Mode to enter system mode from the Home page.
•
Up to scroll up through the menu options.
•
Downs to scroll down through the menu options.
•
OK to select the active option.
•
Clear to return to the previous option or exit service mode.
OK
(Select)
System
Mode
Clear
(Exit Screen)
Power
Up
Down
•
To turn on the Infinea mPOS, tap the Power button
on the top, right corner of the keypad.
The name and version of the Secure Boot Loader and
firmware appear.
Turn on the Infinea mPOS Plus