![Infineon XENSIV CSK PAS CO2 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/infineon/xensiv-csk-pas-co2/xensiv-csk-pas-co2_user-manual_2055409049.webp)
49 of 54
2022-25-04
User Guide for XENSIV™ KIT PAS CO2
Hardware description
Attribute name
Unit
Definition
Range of values
wifiAccessPoints
-
Shows the MAC
addresses of all Wi-Fi
access points that are in
reach of the CSK WLAN.
This information is used
for the location sharing
feature.
fw_version
-
Shows the firmware that
is flashed on the
developer board
15.
Depending on the use case to be evaluated, connect the desired wing board. For example, connect the PAS
CO2 Wing board for evaluating the CO2 sensor or connect the BGT60TR13C radar wing board for evaluating
a presence or entrance counter application. Change the attribute below to activate the application on the
Feather board.
Table 9
Attribute to change the application
Attribute name
Unit
Definition
Range of values
sensor_solution
-
Change the active
application on the
developer board
PAS CO2
–
‘pasco2’
Entrance counter
–
‘counter’
Presence detection-
‘presence’
No application
–
‘none’
Kit_mask_level
-
Bitmask:
INFO = 0x02,
WARNING = 0x04,
MINOR = 0x08,
MAJOR = 0x10,
FATAL = 0x20,
CLD_INFO = 0x40
The flag CLD_INFO
means that the logs will
appear on the cloud in
‘Sensor Hub Logs’ tab
Log value has to be in
decimal
.
The log value of 0x7C (0b 0111 1100)
translates to 124
. So, 124 (0x7C) means
FATAL, MAJOR, MINOR, WARNING will
appear on the cloud in ‘Sensor Hubs
Logs’ tab.
The log value of 0x7E (0b 0111 1110)
translates to 126
. So, 126 (0x7E) means
INFO, FATAL, MAJOR, MINOR, WARNING
will appear on the cloud in ‘Sensor Hubs
Logs’ tab
The default value for kit_mask_level is
124.
After activating the correct application, start your evaluation and change the attributes below to configure
parameters according to your evaluation conditions.
Note:
Changing ‘sensor_
solution
’ reboots the system and it can take up to 1 minute for the system to reboot