![Infineon XENSIV CSK PAS CO2 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/infineon/xensiv-csk-pas-co2/xensiv-csk-pas-co2_user-manual_2055409048.webp)
48 of 54
2022-25-04
User Guide for XENSIV™ KIT PAS CO2
Hardware description
running on the CM4 core. The Wi-Fi scan function is shared by both the cores and this situation arises when the
CM4 is unable to get access to Wi-Fi scan.
Possible solution:
This issue does not have any implication on any other feature but only on the location service feature. The
nodes will not be seen on a map. If this issue arises, reset the node so that the CM4 node is able to successfully
scan the Wi-Fi networks and the fleet monitoring service can get the device details.
12.
SSID “IFX_Sensor” cannot be altered
Possible cause
:
This is the default SSID and password created to create a quick hotspot.
Possible solution:
A personalized hotspot can be created or add your local network and select the same while building the
package.
13.
“program_kit.command” not closing down after programming
Possible cause:
Macintosh OS is not allowing the window to close on its own.
Possible solution:
Close the terminal after “[Process Completed]” appears on the screen.
List of attributes with their definition and possible values.
Note:
The string value of each attribute is case sensitive.
14.
The attributes listed below are common for applications and cannot be changed in the ‘Attribute’ tab. The
t
able below identifies and defines each of them. A user can visualize the value in the ‘Reported value’
column.
Table 8
Common attributes
Attribute name
Unit
Definition
Range of values
ConnectedStatus
-
Reported value shows if
your device is connected
to the sensor cloud or
not
Connected,
Disconnected
LocationSharing
-
Location sharing status,
so you can visualize
where your device is
located
0 or 1
Default value is 1; that
means location sharing
is enabled
If user do not want to