![Infineon IRPS5401 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/infineon/irps5401/irps5401_user-manual_2055180027.webp)
Application Note
27 of 63
V 1.2
2018-12-12
5 Output PMIC Controller/ IRPS5401
User guide with DB295 and DB296 demo boards
7
MTP Programming
7.1
Programming a Single Config File
Inside the PowIRCenter GUI, choose the ‘Utilities’ Tab (1) and Click on ‘Rocky R2 Device Programmer’ (2). The
‘RockyR2Programmer’ box (3) will pop up and display the number of segments left to be programmed in each
section, CNFG, TRIM, USER.
Figure 35
Single config file
For single config file usage (MTP pin offset not used for multiple config file access), the PROGMAX register (4) in
CNFG section must be 0 or 1. Both values indicate a single file is programmed. Check ‘User’, click ‘Check MTP
Left’, and finally click ‘Program’ button. The device will program another segment of the 20 segments available
and the ‘RockyR2Programmer’ box will show another ‘grey’ box in the User section.
7.1
Generating Multiple Config Files (*.mic)
Go to ‘Utilities’
’Multiple Config file Generator’. In the ‘RockyR2MultipleConfigFileGenerator’ dialog box set
the Prog_Max to the number of files to be programmed. Click on the first ‘Click to select a config file’ box and
select the file to be loaded into the segment to be selected by MTP resistor value 845 Ω. Step and repeat to the
n
th