Document Number: 002-10634 Rev. *J
Page
274 of 307
S6J3350 Series
Page
Section
Change Results
223
9. Electric
Characteristics
9.1.4.11 Low
Voltage Detection
(External Voltage)
Low-voltage detection (external low-voltage detection)
Error)
Parameter
Symbol
Pin
Name
Conditions
Value
Unit
Remarks
Min
Typ
Max
Supply
voltage
range
V
DP5
VCC5
-
3.5
*3
-
5.5
*3
V
2.7
*4
-
3.6
*4
Detection
voltage
(before
trimming)
V
DLBT
VCC5
*1
3.6
*3
4.0
*3
4.4
*3
V
When power-
supply voltage
falls and
detection level is
set initially
2.3
*4
2.6
*4
2.9
*4
VCC3
*1
2.3
2. 6
2.9
V
Detection
voltage
(after
trimming)
V
DLAT
VCC5
*1
3.86
*3
4.0
*3
4.14
*3
V
When power-
supply voltage
falls and
detection level is
set initially
Typ±3.5%
*5
2.51
*4
2.6
*4
2.69
*4
VCC3
*1
2.51
2.6
2.69
V
*5: This detection voltage level setting is below the minimum operation assurance voltage (2.7V*4
or 4.0V*3) .Between this detection voltage and the minimum operation assurance voltage,
MCU functions are not guaranteed except for the low voltage detector.
Note that although the detection level is below the minimum operation guarantee voltage,
the LVD reset factor flag is set as the voltage drops below the detection level.
Correct)
Parameter
Symbol
Pin
Name
Conditions
Value
Unit
Remarks
Min
Typ
Max
Supply
voltage
range
V
DP5
VCC5
-
3.5
*3
-
5.5
*3
V
2.7
*4
-
3.6
*4
V
DP3
VCC3
-
2.7
-
3.6
V
Detection
voltage
(before
trimming)
V
DLBT
VCC5
*1
3.6
*3
4.0
*3
4.4
*3
V
When power-
supply voltage
falls and
detection level
is set initially
*1 *5
2.3
*4
2.6
*4
2.9
*4
VCC3
*1 *5
2.3
2. 6
2.9
V
Detection
voltage
(after
trimming)
V
DLAT
VCC5
*1
3.86
*3
4.0
*3
4.14
*3
V
When power-
supply voltage
falls and
detection level
is set initially
Typ±3.5%
*1 *5
2.51
*4
2.6
*4
2.69
*4
VCC3
*1 *5
2.51
2.6
2.69
V
*5: These LVD settings cannot be used to reliably generate a reset before voltage dips below