6 of 8
PN 074-536-P1C
CMS5000 Monitoring System Concentrator Installation Instructions
8
Ensure the concentrator ferrules are properly oriented. Place the ungrooved end of
the concentrator in the left concentrator elbow (A). Tighten the left side of the
concentrator to finger-tight (B). While holding the right concentrator elbow, place the
grooved end of the concentrator into it (C). See
Figure 10 Replace concentrator
9
While holding the right concentrator elbow in place with your fingers, insert and
tighten the bottom screw until finger tight. Continue to stabilize the right concentrator
elbow in place with a 3/8” wrench, insert the top screw and evenly tighten the screws
until snug. Do not overtighten. Overtightening will cause the elbow to turn. See
.
Figure 11 Reinsert the screws
A
B
C