iNetVu Troubleshooting Guide - 1201 Flyaway
Page 46 of 71
Error 0x9008 - PL Jam Error
1. If the Mobile Platform doesn’t physically move
Possible Causes:
•
7000 Controller
•
5 Amp Fuse
•
Flyaway Control Cable
•
Internal Wiring
•
Polarization Motor
a.
Verify if 7000 Controller is outputting 24VDC. Disconnect the motor cable from the back of the
controller, place the volt meter leads on pins 4 and 6 of the controller. Using the 7000 controllers
front panel, select Polarization with HI SPEED ON and hold +. Are you getting 24VDC?
b. If we are not getting voltage from the 7000 controller
, please turn off the controller and verify
the 5A fuse has not blown. If the fuse is blown replace it and try again. If the fuse is not blown,
contact C-Com Technical Support for further assistance.
Warning High Voltage:
Always remove power from the 7000 Controller prior to removing fuse.
Failing to do so can result in personal injury or damage to the controller.
Содержание 1201 Flyaway
Страница 15: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 15 of 71 Assembly and Disassembly...
Страница 16: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 16 of 71 Fly 1201 Physical Outline...
Страница 41: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 41 of 71 Flyaway Control Cable...
Страница 45: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 45 of 71 Flyaway Control Cable...
Страница 49: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 49 of 71 Flyaway Control Cable...
Страница 50: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 50 of 71 SENSOR ERROR...
Страница 54: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 54 of 71 GPS...
Страница 57: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 57 of 71 RF SIGNAL LOSS...
Страница 63: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 63 of 71 MODEM...
Страница 67: ...iNetVu Troubleshooting Guide 1201 Flyaway Page 67 of 71 CANNOT FIND SATELLITE...