MRU
Demo Program Manual
Inertial Labs, Inc
TM
Address:
39959 Catoctin Ridge Street, Paeonian Springs, VA 20129 U.S.A.
Tel: +1 (703) 880-4222, Fax: +1 (703) 935-8377
Website:
www.inertiallabs.com
19
4.2.3. Change of the COM port baud rate
The default baud rate for MRU COM port is set to 115200 bps (maximum for
the standard COM-port). If the host computer requires other baud rate for
the MRU connection, then user can choose one from the next list: 4800,
9600, 14400, 19200, 38400, 57600, 115200, 230400, 460800, 921600 bps.
The same baud rate must be set in the «
Test Options
» of the MRU Demo
Program.
Notes:
1. Baud rate change is implemented in the MRU firmware version since 2.2.0.0 and it is
supported by MRU Demo Program since version 2.0.19.78 from 03/18/2016.
2. To allow baud rate change the MRU unit must be connected to computer and
powered.
3. Standard COM-port of a host computer (PC) does not support baud rate greater than
115200 bps. Therefore some Serial-to-USB adapter should be used for MRU connection
to the host computer.
4. Baud rate must be set the same both for MRU unit and in the MRU Demo Program to
allow this software to control MRU unit.
At the first, set correct COM port baud rate in the «
Test Options
» (see
Fig.4.1). It must be the same as it set in the MRU unit. If COM port baud rate
in the MRU unit is unknown then click «
Auto
» button. After several seconds
window with caption “Serial port baud rate XXXXXX was successfully
determined” will appear (see Fig.4.5) and determined baud rate will appear
in the «
Test Options
» window.