The included long power cable is connecting the control box to the main power.
IMPORTANT:
Only Ultima-Tig and Ultima-Tig-Cut, that is suitable for the voltage and frequency, as the
control box is connected to, shall be connected to the control box.
If the on/off switch on the Ultima-Tig/-Cut grinder is set to ”on”, the grinder is not running, but will start
and stop by activating the on/off button on the side of the AutoGrind module. The control box
automatically supplies the power to the grinder, when the grinding module is turned on. Therefore the
on/off switch on the grinder needs to be ”on”. Otherwise the control box cannot start and stop the
grinder automatically.
6.
Inserting the electrode holder in the AutoGrind
The Electrode is inserted into the electrode holder and securely fastened.
Set the stick-out on the Ultima-Tig/-Cut, as described in step #6 in the
operations manual.
When the electrode holder is inserted in to the AutoGrind module, the
locking pin (black knob) needs to be pressed down to lock the drive unit
and prevent it from rotating.
The electrode holder should be rotated with a light pressure until the
electrode holder locks into the drive unit, you will feel a slight click as the
electrode holder is in position. Next push the electrode holder in and
rotate counter-clockwise until the bayonet lock is holding the electrode
holder in place.
Important:
The locking pin must not be held down, when the AutoGrind is started or pressed down
during grinding. This will destroy the inner parts of the module!
7.
The automatic grinding program
The control box is programmed to run through the following grinding
process that starts when the on/off button is activated:
i.
Ultima-Tig/-Cut grinder is activated and starts to rotate the grinding
disc.
ii.
2 sec. later the AutoGrind module starts to rotate the electrode
holder slowly in 3 sec. This moves the electrode holder towards the
grinding disc, and the grinding of the electrode starts.
iii.
The AutoGrind module is then rotating faster for 15 sec. (the grinding time). The grinding time can
be adjusted as necessary (see step #8)