Procedure
1.
The hydraulic fluid level should always be near the top mark
when the machine is switched off. During production, the oil
level may drop after several consumers have been connected.
Check oil level at the oil sight glass.
2. Visual inspection of the hydraulic fluid. The hydraulic fluid may not exhibit any
foaming or cloudiness at the oil sight glass. In case of problems of this kind,
immediately determine the cause and correct the error. If in doubt, take a
sample for analysis and contact the manufacturer of the hydraulic fluid.
3. Check pressure setting on pressure gauge and adjust if necessary. The value
to be checked here is specified (see hydraulic diagram) and should be between
70-80 bar.
4. Check supply and fluid lines (damage and leakage). Supply and fluid lines must
be checked for damage. Pre-damage such as kinks or abrasions should be
logged and replacement should be initiated.
Maintenance Summary - Care activities
10
Maintenance Instructions
B500
DIE219EN - 05.06.2019
Содержание B500
Страница 8: ...Preface 4 Maintenance Instructions B500 DIE219EN 05 06 2019 ...
Страница 79: ...Service Interval 5 Years Service Interval 5 Years 75 Maintenance Instructions B500 DIE219EN 05 06 2019 ...
Страница 83: ...Service Interval 8 Years Service Interval 8 Years 79 Maintenance Instructions B500 DIE219EN 05 06 2019 ...