6.
Example: Exploded view of fine filter replacement (by FESTO)
1
Filter bowl
2
Separating disk
3
Filter cartridge (check retained particle size)
4
Filter receptacle
5
O-ring
Check fine filter or microfilter, replace if necessary. When removing the filter
bowl, make sure to include the O-ring (5), separating disk (2) and filter
holder (4). Unscrew filter bowl (1) from filter base body and remove filter
cartridge (3) , check, and replace if necessary. Check O-ring (5) , replace if
necessary. Reinstall all parts in reverse order.
Maintenance Summary - Care activities
14
Maintenance Instructions
B500
DIE219EN - 05.06.2019