27 of 37
Indesit
Company
Service Manual UK
English
FAULT CODES - LED Console Models Only
When the machine's Electronics detect a fault:
> All of the Option and Start Led's will Flash Rapidly.
> The machine will continue with Drum Action only for a further 20 minutes.
> The Progress/Warning Lamps will illuminate (continually "ON") to display the relevant Fault Code
For additional Fault Code information see following pages.
STATUS OF LEDs
FAULT
CAUSE
LED COMBINATION
5
4
3
2
1
F01
Motor triac in short circuit or Relay of
motor welded closed
OFF
OFF
OFF
OFF
ON
F02
Blocked motor (fan blocked).
OFF
OFF
OFF
ON
OFF
F03
Front NTC open or short circuit
OFF
OFF
OFF
ON
ON
F04
Pump working when should be off.
OFF
OFF
ON
OFF
OFF
F05
Pump not working when should be on.
OFF
OFF
ON
OFF
ON
F06
Non used, active
OFF
OFF
ON
ON
OFF
F07
Lower element failure
OFF
OFF
ON
ON
ON
F08
Static heater relay welded closed
OFF
ON
OFF
OFF
OFF
F09
Error set-up file. EEPROM is not
programmed or not functioning
OFF
ON
OFF
OFF
ON
F10
Common of heater open, one shot open
OFF
ON
OFF
ON
OFF
F11
Pump open circuit.
OFF
ON
OFF
ON
ON
F12
No communication between display
board and control board
OFF
ON
ON
OFF
OFF
F13
Rear NTC open or short circuit.
OFF
ON
ON
OFF
ON
F14
Upper element failure
OFF
ON
ON
ON
OFF
F15
Dynamic (PD) heater relay welded closed
OFF
ON
ON
ON
ON
F16
Not used, active
ON
OFF
OFF
OFF
OFF
F17
Master relay welded closed
ON
OFF
OFF
OFF
ON
LED 1
LED 2
LED 3
LED 4
LED 5
Option & Start LED’s
will all flash together
when a fault code