16
GB
Table of burner and nozzle specifications
Table 1
Natural gas
Thermal power
kW (p.c.s.*)
Burner Diameter
(mm)
Nominal Reduced
Nozzle
1/100
(mm)
Capacity*
l/h
G25
Rapid (Large)
(R)
100 3.00 0.70
128 332
Semi-rapid
(Medium) (S)
75 1.90
0.40
104 210
Auxiliary
(Small) (A)
51 1.00
0.40
76 111
Supply
pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
25
20
30
*
At 15°C and 1013 mbar - dry gas
Natural G25 P.C.S. = 32.49 MJ/m³
TECHNICAL DATA
Oven dimensions
(HxWxD)
34x39x44 cm
Volume
58 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 18 cm
Burners
may be adapted for use with any
type of gas shown on the data plate
Voltage and
frequency
see data plate
Electric Hotplate
Rapid Ø 180 mm: 2000 W
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens.
Regulation EN 50304
Declared energy consumption for
Natural convection Class –
heating mode
Static
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas)
1275/2008 (Stand-by/ Off mode)
WARNING! The glass lid can
WARNING! The glass lid can
WARNING! The glass lid can
WARNING! The glass lid can
WARNING! The glass lid can
break in if it is heated up.
break in if it is heated up.
break in if it is heated up.
break in if it is heated up.
break in if it is heated up.
Turn off all the burners and
Turn off all the burners and
Turn off all the burners and
Turn off all the burners and
Turn off all the burners and
the electric plates before
the electric plates before
the electric plates before
the electric plates before
the electric plates before
closing the lid.
closing the lid.
closing the lid.
closing the lid.
closing the lid.
S
S
R
A
KN3G11S/NL
K3G11/O
K3G11S/O
Содержание K3G11/O
Страница 35: ...FR 3 5 3 5 3 5 3 5 3 5...
Страница 36: ...36 36 36 36 36 FR 03 2011 195048029 03 XEROX FABRIANO...