3
F
r
ont
Hooking position
Bac
k
for top
H
=
40
mm
Use the hooks contained in the accessory pack
Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This
must be placed at a minimum distance of 20 mm from
the lower part of the hob.
V
e
nt
ila
t
i
on
To ensure adequate ventilation, the back panel of the
cabinet must be removed. It is advisable to install the
oven so that it rests on two strips of wood, or on a
completely flat surface with an opening of at least 45 x
560 mm (
see diagrams
).
!
The hob can only be installed above built-in ovens with a
cooling ventilation system.
E
le
c
t
r
i
c
al
c
onne
c
tion
The cooktops fitted with a tripolar electrical supply
cord are designed to be be used with alternating
current according to the indications on the rating
plate located under the cooktop. The earthing wire
can be identified by its yellow-green colour.
In the case of installation over a built-in electric
oven, the electrical connections for the cooktop and
oven should be independent, not only for safety
purposes, but also to facilitate removal of one or
both in the future.
Elec
t
rical
C
onn
ec
t
i
on
f
o
r
Gas
C
oo
k
to
p
Fit the supply cord with a standard plug for the
demand rate indicated on the rating plate or connect
it directly to the electrical mains. In the latter case, a
single pole switch must be placed between the
appliance and the mains, with a minimum opening
between the contacts of 3 mm in compliance with
current safety codes (the earthing wire must not be
interrupted by the switch). The power supply cord
must be positioned so that it does not reach a
temperature in excess of 50°C above room
temperature at any point.
The installer must ensure that the correct electrical
connection has been made and that it is compliant
with safety regulations.
Before making the actual connection, make sure
that:
The fuse and electrical system can withstand the
load required by the appliance;
That the electrical supply system is equiped with
an efficient earth hook-up according to the norms
and regulations prescribed by law;
That the plug or switch is easily accessible.
The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
-
Ear
t
h
Blue
- Neutral
Brown
- Live
As the colours of the wires in the mains lead may
not correspond with the coloured markings
identifying the terminals in your plug, proceed as
follows:
Connect the Green & Yellow wire to the terminal
marked
E
or
or coloured Green or Green &
Yellow.
Connect the Brown wire to the terminal marked
L
or
coloured Red.
Connect the Blue wire to the terminal marked
N
or
coloured Black.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced
by authorised technicians only (
see Assistance
).
The manufacturer declines any liability should
these safety measures not be observed.
G
as
c
onne
c
tion
The appliance should be connected to the main gas supply
or to a gas cylinder in compliance with current national
regulations. Before carrying out the connection, make sure
the cooker is compatible with the gas supply you wish to
560 m
m.
45 m
m.