background image

G

B

2

 Before operating your new appliance please read this

instruction booklet carefully. It contains important information

for safe use, installation and care of the appliance.

 Please keep these operating instructions for future

reference. Pass them on to possible new owners of the

appliance.

Positionin

g

 Keep packaging material out of the reach of children. It

can become a choking or suffocation hazard (

see

Precautions and tips

).

 The appliance must be installed by a qualified professional

according to the instructions provided. Incorrect installation

may cause harm to people and animals or may damage

property.

 This unit may be installed and used only in permanently

ventilated rooms in accordance with British Standard Codes

Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891

Current Editions. The following requirements must be

observed:
• The room must be equipped with an air extraction system

that expels any combustion fumes. This may consist of a

hood or an electric fan that automatically starts each time

the appliance is switched on.

• The room must also allow proper air circulation, as air is

needed for combustion to occur normally. The flow of air

must not be less than 2 m

3

/h per kW of installed power.

The air circulation system may

take air directly from the outside

by means of a pipe with an inner

cross section of  at least 100 cm

2

;

the opening must not be

vulnerable to any type of

blockages.

The system can also provide the

air needed for combustion

indirectly, i.e. from adjacent rooms

fitted with air circulation tubes as

described above. However, these

rooms must not be communal

rooms, bedrooms or rooms that

may present a fire hazard.

• Liquid petroleum gas sinks to the floor as it is heavier

than air. Therefore, rooms containing LPG cylinders must

also be equipped with vents to allow gas to escape in

the event of a leak. As a result LPG cylinders, whether

partially or completely full, must not be installed or

stored in rooms or storage areas that are below ground

level (cellars, etc.). It is advisable to keep only the

cylinder being used in the room, positioned so that it is

not subject to heat produced by external sources

(ovens, fireplaces, stoves, etc. ) which could raise the

temperature of the cylinder above 50°C.

F

itting

 

the

 

appliance

Gas and mixed hobs are manufactured with type X

degree protection against overheating. The following

precautions must be taken when installing the hob:
• Kitchen cabinets adjacent to the appliance and taller

than the top of the hob must be at least 600 mm from

the edge of the hob.

• Hoods must be installed according to their relative

installation instruction manuals and at a minimum

distance of 650 mm from the hob.

• Place the wall cabinets adjacent to the hood at a

minimum height of 420 mm from the hob (

see figure

).

If the hob is installed beneath a

wall cabinet, the latter must be

situated at a minimum of 700 mm

above the hob (

see figure

).

• The installation cavity should have the dimensions

indicated in the figure. Fastening hooks are provided,

allowing you to fasten the hob to tops that are between

20 and 40 mm thick. To ensure the hob is securely

fastened to the top, we recommend you use all the

hooks provided.

555 

mm

475 

m

m

55

 mm

Hoo

fastening

 

diagra

m

Hooking position

Hooking position

for top

 

H

=

20

 mm

for top 

H

=3

0

 mm

Installation

Enlarging the ventilation slot
between window and floor.

Adjacent
Room

Room to be
Vented

A

Examples of ventilation holes
for comburant air.

In a chimney stack or branched flue. 
(exclusively for cooking appliances)

Directly to 
the Outside

600mm min.

600mm min.

700mm min.

Содержание IP640SUK

Страница 1: ...Burner and nozzle specifications Description of the appliance 6 Overall view Start up and use 7 Practical advice on using the burners Precautions and tips 8 General safety Disposal Maintenance and care 9 Switching the appliance off Cleaning the appliance Gas tap maintenance Troubleshooting 10 OperatingInstructions G B English 1 GB ...

Страница 2: ... to the floor as it is heavier than air Therefore rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak As a result LPG cylinders whether partially or completely full must not be installed or stored in rooms or storage areas that are below ground level cellars etc It is advisable to keep only the cylinder being used in the room positioned so ...

Страница 3: ...iance with current safety codes the earthing wire must not be interrupted by the switch The power supply cord must be positioned so that it does not reach a temperature in excess of 50 C above room temperature at any point The installer must ensure that the correct electrical connection has been made and that it is compliant with safety regulations Before making the actual connection make sure tha...

Страница 4: ...se of the hob or on the packaging the burner nozzles should be replaced as follows 1 Remove the hob grids and slide the burners off their seats 2 Unscrew the nozzles using a 7 mm socket spanner and replace them with nozzles for the new type of gas see table 1 Burner and nozzle characteristics In the case of the Mini WOK burner use a spanner with a 7 mm opening to unscrew the nozzle see figure 3 Re...

Страница 5: ... Nominal mbar Minimum mbar Maximum mbar 28 30 20 35 37 25 45 20 17 25 At 15 C and 1013 mbar dry gas Propane P C S 50 37 MJ kg Butane P C S 49 47 MJ kg Natural P C S 37 78 MJ m3 A S R S A S MW S A MW RR S S IP 751 S C UK IP 640 S UK IP 641 S C UK DATA PLATE Electrical connections See data plate This appliance conforms to the following European Economic Community directives 2006 95 EEC dated 12 12 0...

Страница 6: ...o cook with Control Knobs for GAS BURNERS adjust the size of the flame GAS BURNER ignition enables a specific burner to be lit automatically SAFETY DEVICE stops the gas flow if the flame is accidentally extinguished Support Grid for COOKWARE GAS BURNERS Control Knobs for GAS BURNERS GAS BURNERS Support Grid for COOKWARE Control Knobs for GAS BURNERS SAFETY DEVICES Ignition for GAS BURNERS ...

Страница 7: ...he corresponding knob all the way in and then turn it anti clockwise to the High setting keeping it pressed in until the burner lights If a flame is accidentally extinguished turn off the control knob and wait for at least 1 minute before trying to relight it To switch off the burner turn the knob in a clockwise direction until it stops when reaches the position Start up and use Only available on ...

Страница 8: ...rs carried out by inexperienced persons may cause injury or further malfunctioning of the appliance Contact a Service Centre see Assistance Always make sure that pan handles are turned towards the centre of the hob in order to avoid accidental burns Do not close the glass cover if present when the gas burners are still hot Do not use unstable or deformed pans The appliance should not be operated b...

Страница 9: ...nic instant lighting devices should be cleaned frequently and the gas outlet holes should be checked for blockages Stainless steel can be marked by hard water that has been left on the surface for a long time or by aggressive detergents containing phosphorus After cleaning rinse and dry any remaining drops of water The position of the central grid may be inverted If this happens the spokes will ap...

Страница 10: ...pliance You pressed the knob all the way in You keep the knob pressed in long enough to activate the safety device The gas holes are not blocked in the area corresponding to the safety device The gas holes are not blocked There are no draughts near the appliance The minimum setting has been adjusted properly The bottom of the cookware is perfectly flat The cookware is positioned correctly at the c...

Страница 11: ...GB 11 ...

Страница 12: ...GB 12 01 2009 195072559 00 XEROX FABRIANO ...

Отзывы: