9
GB
Table of burner and nozzle specifications
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Nominal Reduced
(mm)
(mm)
***
**
(mm)
(mm)
Fast
(Large)(R)
100
3.00
0.7
41
87
218
214
128
286
143
286
Semi Fast
(Medium)(S)
75
1.90
0.4
30
70
138
136
104
181
118
181
Auxiliary
(Small)(A)
51
1.00
0.4
30
52
73
71
76
95
80
95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
S S
R
A
TECHNICAL DATA
Oven dimensions
(HxWxD)
Volume
60 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 23 cm
Power supply voltage
and frequency
see data plate
Energy Label
Declared energy consumption for
Natural convection Class
Heating mode: Convection
Energy consumption for Forced
convection heating mode:
Fan assisted
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.
I5G52G /UA
340x 410x 424 mm
Содержание I5G52G /UA
Страница 30: ...30 UA ...
Страница 31: ...31 UA ...
Страница 32: ...12 2013 195119118 00 XEROX FABRIANO 32 UA ...