![Indel B TB118 DD Steel Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/indel-b/tb118-dd-steel/tb118-dd-steel_instructions-for-use-manual_2051414032.webp)
30
TB STEEL DOUBLE DOOR
TB STEEL DOUBLE DOOR_24-01-2019
MAINTENANCE
WARNING!
Before carrying out any maintenance operations on the appliance, disconnect the power cable from
the plug.
CLEANING
• Regularly clean the inside and outside of the appliance using only warm water and a neutral detergent.
• Subsequent to washing, rinse with clean water and dry thoroughly using a soft cloth.
• Do not use the following: special glass and mirror cleaning products, liquid, powder, or spray detergents,
alcohol, ammonia or abrasive products.
• If you are not using the refrigerator, we suggest cleaning it well inside and leaving the door ajar to
ventilate the interior.
HELPFUL ADVICE
Where the refrigerator does not function or functions incorrectly, before contacting one of our technical
assistance centres, ensure that:
a) there is a power supply.
b) the voltage complies with that indicated on the plate.
c) the connections and poles are correct.
d) the ventilation grids are not obstructed.
e) the appliance unit is not placed near to a heat source.
f) the power supply fuse is not interrupted.
WARNING!
The power cable must only be replaced by qualified technical personnel and by an assistance body authorised
by the Manufacturer.
Indel B will not assume any responsibility in the instance where the instructions in this present
manual are not fully respected.
FAULTS
NUMBER OF
FLASHES
ERROR TYPE
E1
Battery protection cut-out
(The voltage is outside the cut-out setting).
E2
Fan over-current cut-out
(The fan loads the electronic unit with more than 1A
peak
).
E3
Motor start error
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
E4
Minimum motor speed error
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed 1,850 rpm).
E5
Thermal cut-out of electronic unit
(If the refrigeration system has been too heavily loaded, or if the ambient temperature
is high, the electronic unit will run too hot).
LL
Faulty temperature sensor
(the temperature sensor is disconnected or defective)
HH
Faulty temperature sensor
(the temperature sensor is defective)
Содержание TB118 DD Steel
Страница 2: ......
Страница 94: ...92 EU 19 2012...
Страница 95: ...TB STEEL DOUBLE DOOR 2019 01 24_ TB STEEL 93 Indel B E1 E2 1 E3 5 E4 1 850 E5 LL HH...
Страница 96: ...94 0 24 30 55...
Страница 97: ...TB STEEL DOUBLE DOOR 2019 01 24_ TB STEEL 95 120 60 240...
Страница 98: ...96 MAX MIN MIN MAX MIN SET MAX MAX SET...
Страница 103: ...TB STEEL DOUBLE DOOR 2019 01 24_ TB STEEL 101 50 240 220 24 12 15 15 4 5 AWG14 2 2 1 4 6 AWG12 2 3 3...
Страница 104: ...102...
Страница 105: ...TB STEEL DOUBLE DOOR 2019 01 24_ TB STEEL 103 1 2 3 4 24 12 5 240 6 1 1 2 5 6 4 3...
Страница 106: ...104 R600a...
Страница 108: ...106 TB STEEL TB65 DD STEEL TB92 DD STEEL TB118 DD STEEL TB65 DD STEEL TB92 DD STEEL TB118 DD STEEL...