28
RM7
RM7_(DC)_IM_20190723
USING THE CONTROL PANEL
•
To switch the device on, press button
2
.
•
To switch it off, press button
2
for 5 seconds.
•
The green LED
4
flashing intermittently indicates that the device is heating up and has not yet reached
its operating temperature.
•
As soon as the device reaches the set operating temperature, the green LED
4
remains steadily on; the
device is ready for use.
SETTING THE INTERNAL TEMPER ATURE
•
Press buttons
1
and
2
at the same time for 10 seconds to access the temperature adjustment function:
the display
3
with the set temperature will flash.
•
Use buttons
1
and
2
individually to increase or decrease the temperature setting.
•
When the desired temperature, between 32°C and 40°C, is reached, there is no need to press any
other button as the temperature setting is saved automatically.
AL ARMS
If the set temperature undergoes a variation greater than ± 1.5°C, the red LED
5
starts to flash intermittently,
together with an audible alarm (buzzer).
Check and eliminate the cause of the temperature variation and deactivate the alarm state by pressing
buttons
1
and
2
at the same time.
DESCRIPTION OF THE CONTROL PANEL
1
Alarm set-reset or temperature increase button
2
Alarm set-reset or temperature decrease button
3
Display
4
Green proper functioning LED
5
Red alarm LED
ALARM RESET
OK
SET
ON
OFF
1
2
3
4
5
Содержание RM7
Страница 2: ......
Страница 3: ...ITALIANO ENGLISH ESPA OL FRAN AIS DEUTSCH 3 16 17 30 31 44 45 58 59 72 RM7 RM7_ DC _IM_20190723...
Страница 4: ...2 RM7 RM7_ DC _IM_20190723...
Страница 9: ...ITALIAN O 7 278 20 180 DIMENSIONI D INGOMBRO...
Страница 23: ...E N G LIS H 21 278 20 180 OVERALL DIMENSIONS...
Страница 37: ...E S PA O L 35 278 20 180 DIMENSIONES TOTALES...
Страница 51: ...FR AN AIS 49 278 20 180 DIMENSIONS HORS TOUT...
Страница 65: ...D EUTSCH 63 278 20 180 AUSSENABMESSUNGEN...
Страница 75: ...D EUTSCH 73...
Страница 76: ......