Safety:

Please follow the below safety precautions. If there are any questions, please call INDCO at 800-942-4383. Please read this com-
plete manual before trying to operate your mixer.  Failure to follow these instructions could result in serious bodily injury or death.

 

• Do not touch moving parts while mixer is operating.

 

• Do not wear loose-fitting clothes or jewelry around an operating mixer. Keep all hands, feet, clothes, neckties, necklaces  

 

   and other ojects clear of moving parts. 

 

• Never move the unit without a suitable lifting device. 

 

• Have a qualified individual bring power to the unit. 

 

• Always ground the unit. Never use an extension cord. 

 

• Never run the unit in open air.

 

• Never adjust the speed without the unit running.

 

• Always lockout the power when working on the unit.

ELECTRIC MOTOR SAFETY

:

Motors should be installed, protected and fused in accordance with latest issue of National Electrical Code, NEMA Standard 
Publication No. MG 2 and local codes. Frames and accessories of motors should be grounded in accordance with National 
Electrical Code (NEC) Article 430.  For general information on grounding refer to NEC Article 250. Not all rotating parts are 

guarded.  Keep hands and clothing away from moving parts. Trained, qualified personnel should make electrical repairs and non-

standard connections. If environment has hazardous combustible fumes present, use only explosion-proof electric motors.

AIR MOTOR SAFETY

:

The air motor is designed to be driven by compressed air and under no circumstances be driven with any other gases.  Fluids, 
particles, solids or any substance mixed with air, particularly combustible substances likely to cause explosions, must not drive air 
motor.

 

• Do not drive with flammable or explosive gases or operate unit in an atmosphere containing them.

 

• Air motor is designed for air only.  Do not allow corrosive gases or particulate material to enter motor.  Water vapor, oil-   

 

   based contaminants, or other liquids must be filtered out.

 

• Do not use a hammer or force coupling or drive pulley onto shaft when installing drive onto air motor.  This causes end   

 

   thrust that could damage air motor.

 

• Ambient temperature should not exceed 250°F.

 

• Beware of any exposed and/or movable parts.  Proper guards should be in place to prevent personal and/or property    

 

  damage.

 

• Solid or liquid material exiting unit can cause eye or skin damage.  Keep away from air stream.

 

• Always disconnect air supply before servicing.

 

• Do not allow air motor to “run free” at high speeds with no loads.  Excessive internal heat build-up, loss of internal  

 

 

   clearances and rapid motor damage will result.

 

• Some models may exceed 85dB(A) sound level.  

General:

INDCO bracket mount mixers are excellent for agitation of light to medium viscosity materials.  The standard mounting bracket 

fits totes and other containers between 34” and 48” wide.  These units are easily movable from one container to another.  
 

• TEFC models are supplied with cord, plug and switch.  

 

• EP models must be wired by the user.  

 

• Variable Speed Electric models have a speed controller mounted on the mixer, pre-wired and power cord.

BT Series - DIRECT Drive

Standard electric models have output speed of 1750RPM.  Variable speed electric motors run from 35 to 1750RPM and air 

models run from 300 to 3000RPM.
BGF Series - GEAR Drive

Standard electric models have output speed of 230RPM.  Variable speed electric motors run from 0 to 230RPM and air models 

run from 40 to 400RPM.

INDCO, Inc. • M-M-30105 mixer manual BT & BGF Series • 1/9/14 • Page 2 of 11

Содержание BGF Series

Страница 1: ...All component parts of our products are covered by this warranty except for normal wear items such as belts or impellers We cannot be responsible for damage or abuse to equipment caused by improper in...

Страница 2: ...o cause explosions must not drive air motor Do not drive with flammable or explosive gases or operate unit in an atmosphere containing them Air motor is designed for air only Do not allow corrosive ga...

Страница 3: ...t screws as far as possible without removing them Insert mixing shaft into the coupler as far as it will go Tighten the set screws firmly to secure the shaft to the coupler Impeller Placement For mixe...

Страница 4: ...secure the shaft to the propeller Impellers BGF Series The standard impellers arefFolding type To install follow same procedure as BT Series above Impeller Shaft BGF series The impeller shaft mounts t...

Страница 5: ...the air valve is in the closed position then connect air supply Check rotation to be sure the mixer shaft is rotating in a clock wise direction looking downward into the container Once the mixer is i...

Страница 6: ...itions after the initial oil change the oil should be changed after every 2 500 hours of operation or every six months whichever occurs first Under severe conditions rapid temperature changes moist di...

Страница 7: ...Muffler metal N K208 Repair Kit MTR 1 2 56C 1 TEFC Motor electric fixed speed 1 2 HP Explosion Proof 115 230VAC single MTR 1 2 56C 1 TEFC Motor electric fixed speed 1 2 HP TEFC 115 230VAC single phas...

Страница 8: ...tch SWT GUARD Switch guard MTR 108022 Motor electric variable speed 1 HP TEFC 115VAC to 90VDC single phase MTR DC CONTROL DC motor controller variable speed 1 3 thru 2HP CPG 14 3 Cord 14 3 5 with plug...

Страница 9: ...Parts List BT Series Mixer INDCO Inc M M 30105 mixer manual BT BGF Series 1 9 14 Page 11 of 11 502 505 504 503 506 501 509 508 300 400 210 101 102 100...

Страница 10: ...4 dia x 40 long stainless N SHF 7540 1 400 Impellers specify model 1 2 401 Set screw not shown specify model 2 4 BRACKET ASSEMBLY 500 Bracket Ass y Complete consisting of BT 403 1 501 Adjustable brac...

Страница 11: ...Parts List BGF Series Mixer INDCO Inc M M 30105 mixer manual BT BGF Series 1 9 14 Page 11 of 11 100 102 101 204 200 202 201 509 203 300 400 401 502 505 504 503 506 508 501 204...

Страница 12: ...Impellers folding 10 diameter x 3 4 bore stainless FP107 2 400 Impellers folding 12 diameter x 3 4 bore stainless FP127 2 400 Impellers folding 14 diameter x 3 4 bore stainless FP147 2 401 Set screw...

Страница 13: ...ady be secured to the bracket fig A 2 Adjust height of clamp such that the lower J Hook connects with wire frame as shown 3 Clamp should be located so that the handle is vertical 4 Use bolts to secure...

Страница 14: ...ap between the J Hook and the upper wire frame as shown in Fig C This will ensure secure clamping on cage with toggle handle in vertical position 7 Release clamp and install remaining hardware INDCO I...

Страница 15: ...racket mount has not yet been fastened and should look similar to the picture in FIG D 9 Secure the two halves together with the included hardware as shown Note that the hardware should be located uti...

Страница 16: ...ed Please note that there must be a minimum of an 1 8 gap between the J hook and the tote wire frame as shown in order to secure properly 11 Cage style as shown below please follow the instructions fo...

Страница 17: ...1 2 to 2 from the IBC tote cage as shown 13 Adjust bracket to set of mounting holes as shown INDCO Inc M M 30105 mixer manual BT BGF Series 1 9 14 Page 11 of 11 Tighten nut until desired tension is ob...

Страница 18: ...tch in the up position as shown At the same time loosen the top nylock nut so that the latch will fit snug with the tote rail INDCO Inc M M 30105 mixer manual BT BGF Series 1 9 14 Page 11 of 11 Tighte...

Страница 19: ...begin to tighten this nut release and engage the latch to check the tension Adjust the tension as desired to secure the latch to the tote frame INDCO Inc M M 30105 mixer manual BT BGF Series 1 9 14 P...

Отзывы: