5
w w w . i n a z u m a - o n l i n e . c o m
2.5. Initial operation and functioning of
the control
The commissioning of the control is done by establishing
the power connection. To do this, plug the power plug of
the controller into a 230 V Schuko socket.
The starting process of the controller takes about 1 to 2
minutes. The controller acknowledges the successful start
with a long beep.
If there is no signal tone from the controller even after the
2 minutes have elapsed, please check the integrated fuse
of the controller (see chapter 2.3.).
The rinsing process will start automatically depending on
the pollution level of the drum.
When the drum is soiled to a certain level, the float switch
SS2 activates the rinsing process.
The drum filter control is equipped with a malfunction
detector. When a malfunction is detected, the control
reports a malfunction by sending out a beeping sound:
Beep sound for 1 second every 5 seconds.
ATTENTION (gravity version only)
You have to pay attention to the water level if
you have a pond without an automatic water
refill system. If the water sinks below the level
of the bottom float switch, the filter will turn off
automatically, or else a continuous irrigation
would occur.
Inazuma
®
offers an automatic pond level
regulation (item no. IK5001)
!
2.6. Depiction of the float switches
SS1 = single float switch
SS2 = double float switch
SS2t = top floater of the double float
switch
SS2b = bottom floater of the double
float switch
2.4. Mounting of the control unit
On the back of the control unit is a stainless steel bracket
with screw holes. This allows the controller to be mounted
with screws on a wall or by hanging in the module retainer
(IK5010).
Openings in the bracket
for wall mounting by screws /
for hanging in the module retainer.