5. Water level regulation WebCSA
(optional)
The Inazuma water level control is an electric, fully
automatic control unit for the compensation of water
losses on koi-, swimming-, garden- and ornamental ponds.
It consists of
• Magnetic valve 230 V / 50 Hz with 5 m connection cable
• Water sensor incl. 10 m connection cable
Activation by code (internet access required for activation).
5.1. Functioning
Water level OK
Water level sensor is in water > magnetic valve closed
> no refilling
Water level sinks
As soon as the water level sensor is outside the water for
more than 20 seconds (wave suppression), the solenoid
valve opens. Water is refilled.
Overfilling time function
The level control is equipped with a so-called overfill time
function to prevent constant on and off switching of the
solenoid valve.
This means that the water level regulator keeps refilling
after reaching the desired water level for the duration that
you can adjust in the “overfill time” option in the app. Only
then does the solenoid valve close.
This prevents the regulation from switching on too
frequently over the course of the day if the water level
drops too low.
Therefore, the sensor should be installed about two
centimetres below the desired maximum pond water level.
Safety function
The refill time is limited to a maximum of 60 minutes.
After this time, the solenoid valve switches off. The app
displays “overfill protection”. At the same time, an internal
countdown is triggered which returns the level regulation
to the automatic operating mode after 12 hours.
Alternatively, the level regulation can be reactivated
manually in the app.
5.3. Installation sensor & magnetic valve
Water level sensor
Install the water level sensor in the pond at the desired
height so that the two contacts are
horizontally
approx.
2 cm below the water surface or the maximum pond
water level.
The sensor can be attached by a screw through the
existing hole on the sensor.
Magnetic valve
The water supply of the solenoid valve can take place for
example by the domestic water connection. All Inazuma
filters have a hole to attach the magnetic valve.
Valve inlet (left picture)
The flow direction of the water is marked on the underside
of the solenoid valve by an arrow.
In order to avoid damage to the water network, we
recommend the installation of a water hammer
damper. Alternatively, an approx. 100 cm long
hose can be mounted directly in front of the valve
in the supply line to the solenoid valve.
When using 3/4 “double nipples for connection
(not included), always use plastic nipples.
Mains plug:
Only connect the mains plug after making sure that all
other steps have been carried out correctly. Your pond
level regulation WebCSA is now operational.
5.4. Winter operation
At temperatures below 0 °C, it must be ensured
that the water pipe or the magnetic valve can not
freeze or be damaged.
!
!
!
5.2. Connection to the control
Always disconnect the power plug before connecting /
disconnecting components or opening the control unit!
Magnetic valve
Water level sensor