22
Operation
(Reference)
The toilet emits a sound of blowing wind while Room Refresh is operating.
Ozone produced by the ion generator can sometimes have its own odor. The concentration is very minor and is
not a health concern.
Make sure that auto seat open is turned on before using this function.
*1.
(Floating mold spores)
Testing
organization:
Ishikawa Health Service Association
Testing
method:
Plasmacluster ions were released into a laboratory equivalent to a room size of approximately 132 square feet. The amount of
oating mold spores was then analyzed with an air sampler.
(Plasmacluster ion concentration: 3,000/cm
3
)
Test result:
99.0% elimination of bacteria after approximately 195 minutes
Effectiveness: A similar effect can be expected when using the same concentration of ions as that released by the plasmacluster ion
generator used in the test into the test space of approximately 132 square feet.
*2.
(Deposited bacteria)
Testing
organization:
Japan Food Research Laboratories
Testing
method:
Bacteria was deposited onto a test slide in a test space of approximately 9 L. Plasmacluster ions were then released into the air.
The test slide was collected from the test space. The rate of bacteria removal was analyzed after a culture period of two days.
(Plasmacluster ion concentration: 90,000/cm
3
)
Test result:
Over 99% removal of bacteria at the 40-hour mark.
Test certi cate number: 12086808001-01
Effectiveness: Actual results in actual spaces may vary depending on usage and environmental conditions such as temperature and
humidity. Plasmacluster ions are effective against bacteria that has deposited in the toilet bowl. The toilet must still be cleaned
on a regular basis.
*3.
(Odor-causing bacteria)
Testing
organization:
Internal testing
Testing
method:
Odor-causing bacteria was deposited onto a test slide in a test space of approximately 9 L. Plasmacluster ions were then
released into the air.
The test slide was collected from the test space. The rate of bacteria removal was analyzed after a culture period of two days.
(Ion concentration: 70,000/cm
3
)
Test result:
Over 99.0% removal of bacteria at the 30-hour mark.
Effectiveness: Actual results in actual spaces may vary depending on usage and environmental conditions such as temperature and
humidity. Plasmacluster ions are effective against bacteria that has deposited in the toilet bowl. The toilet must still be cleaned
on a regular basis. The odor removal effect may vary depending on the type and strength of the odor.
Room Refresh operation method
Both positive and negative plasmacluster ions are released into the toilet once per day to refresh the space around the
toilet through the synergistic effects with the deodorizer.
* Once the switch is pressed, the function will begin two operate two hours before this
timing, starting from the next day. Once enabled, the function will continue to operate
inde nitely.
* The toilet lid will open while Room Refresh is operating.
* The function will not operate on days in which the toilet is in use at the time the function would normally start to
operate. The function will operate at the con gured time again on the next day.
* If any other operation is performed during this process, operation stops and will not restart again for that day.
The function will operate at the con gured time again on the next day.
6:00
Set to
operate at 6 AM
Next day
2 days later
OFF
ON
8:00
10:00
2:00
6:00
4:00
8:00
4:00
6:00
1 hour
1 hour
Set
Room Refresh
Содержание DV-S618
Страница 62: ...GCW 1356 EG 16110...