background image

 

 

8

 

Operating manual 

AC-A3016 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Connection 

CAUTION: The active power distributor is equipped with safety features (see pages11- 12)

 

which may 

cause  all  connected  components  to  be  switched  off  suddenly!  In  certain  circumstances,  this  could 

damage components or result in the loss of data. It is IMPERATIVE that table 1 on page 10

 

is observed 

in order to determine which components may not be suitable for use with the device or which may be 

at risk of being damaged.

 

 

1.  Before  connecting  the  AC-A3016  active  power  distributor,  please  switch  off  all  components 

and un-plug the respective mains plugs. 

 

2.  If your system already has a power strip, please remove it. 

 

3.  Position  the  active  power  distributor  next  to  your  other  components.  The  active  power 

distributor  may  not  be  covered  and  should  be  sufficiently  ventilated  (refer  to  Set-up            

on  page  6).  Note  the  length  of  the  cables  of  the other components which will be connected   

to  the  active  power  distributor.  The  cables  should  be  sufficient  in  length  and  may  not  be 

crimped, crushed or stretched under too much tension. 

 

4.  The  AC-A3016  is  equipped  with  4  groups,  each  with  2  sockets  (items  7-10).  Every  group    

can  be  assigned  to  a  special  filter  (page  14)  perfectly  tailored  to  device  characteristics.      

The  following  filters  are  available:  Filter  Off  |  High  Power  |  Analogue  |  Digital  |  Group  D  | 

Video.  The groups can also be switched off individually (page 15). 

 

Please note that socket groups B, C and D can each be loaded with a maximum of 4 ampere 

(4A / 920 W in total - distributed to two sockets).. 

 

The  device  categories  are  described  in  more  detail  on  page  10.  You  can  find  an  example      

on  page  21  and  a  table  where  you  can  plan  the  device  connections  and  the  preset 

configurations on page 23. 

 

The  voltage  regulators  for  groups  B  -  C  –  D  can  be  loaded  with  a  maximum  of  920 W/4 A.      

The peak current here is 25 ampere. 

 

5.  Plug the mains power cable (item 4) of the active power distributor into a wall socket.

 

 

 

CAUTION: It is imperative that the phase orientation on the mains plug is observed! 

The  pin  on  the  SAFETY  socket  with  the  white  indicator  dot  MUST  be  connected  in 

phase.  Non-compliance  will  significantly  reduce  the  functionality  and  performance 

of the active power distributor. 

 

An  active  screening  tester  has  been  supplied  in  order  to  determine  the  phase  of  the  power 

socket (see page 13). If in doubt, please consult a qualified electrician. 

 

6.  Before you start running all components now,  please check again the whole installation of 

your components. 

Содержание Referenz AC-A3016

Страница 1: ...O P E R A T I N G M A N U A L AC A3016 Referenz Operating Manual ...

Страница 2: ...rformance at lower coast Striving to be better PREMIUM Premium the in akustik class for state of the art technology Gets the most from your audio video system Built on a love of superior performance Our quality standards A passionate family in akustik is a quality brand and respected around the world For more than 30 years in akustik has put its heart and soul into the business of audio and video ...

Страница 3: ...ABLE DEVICE CONNECTION ACTIVE SCREENING PHASE TESTER Congratulations on your purchase of an AC A3016 active power distributor This high tech product was developed drawing on the latest technological advancements and is equipped with the most up to date technological features So that you can enjoy your new product from the very beginning we ask that you carefully read the following operating manual...

Страница 4: ...filled with water or other liquids e g vases etc 4 Protecting the product Do not under any circumstances expose the devices to high levels of humidity Extreme temperature fluctuations humidity and extended exposure to light can damage the devices and alter their appearance Make sure that no foreign objects or liquids enter the device 5 Positioning Do not position the product near sources of heat h...

Страница 5: ...ns switch on the back of the device should be switched off and the mains plug should be disconnected The mains plug and the mains on off switch for the device should be easily accessible 8 Overload In cases of extreme overload it is possible for individual components to burn through despite multiple fuses It is also theoretically possible although we are not aware of any such incidents that such o...

Страница 6: ... and lint free cloth or with a brush Do not under any circumstances use scouring agents alcohol benzene furniture polish or similar substances Package contents 1 x AC A3016 active power distributor 1 x active screening phase tester 1 x operating manual Set up The AC A3016 active power distributor is a high performance power source which can become hot during operation In order to avoid malfunction...

Страница 7: ...f the AC sockets is always on the side of the AC power cable on the left when seen from behind as marked here with a RED dot 1 STAND BY BUTTON 2 STAND BY LED RED 3 INDICATOR LED GREEN 4 AC POWER CABLE 5 MAINS SWITCH 6 OPERATING VOLTAGE INDICATION 7 2 X SOCKETS GROUP A HIGH POWER 16A MAX 8 2 X SOCKETS GROUP B ANALOG 4A MAX 9 2 X SOCKETS GROUP C DIGITAL 4A MAX 10 2 X SOCKETS GROUP D VIDEO 4A MAX 11 ...

Страница 8: ...0 Every group can be assigned to a special filter page 14 perfectly tailored to device characteristics The following filters are available Filter Off High Power Analogue Digital Group D Video The groups can also be switched off individually page 15 Please note that socket groups B C and D can each be loaded with a maximum of 4 ampere 4A 920 W in total distributed to two sockets The device categori...

Страница 9: ...ge power output too high can cause the power distributor to reach the temperature limit at which point it will switch off more under Safety features on page 12 The following diagram is intended to provide a better understanding of how the active power distributor s power handling capacity is dependent on time Devices have different performance characteristics We differentiate between devices with ...

Страница 10: ...nt high high high high very high Yes Household appliances Washing machine Clothes dryer Hair dryer Clothes iron Waffle iron deep fryer Microwave Oven hot plates high constant high constant high constant high constant high constant high constant high constant high constant high constant very high very high very high very high very high very high very high very high very high Not suitable The active...

Страница 11: ...se the internal voltage reference in terms of temperature During the warm up phase the voltage at the plug sockets on the active power distributor can be slightly higher than 230V but still within standard mains tolerance This poses no problem for the connected devices If you would like to make an A B comparison with another mains distributor e g your old power strip you should first allow the AC ...

Страница 12: ...ure drops below 65 C the sockets switch on again and the device can be operated normally 5 Overload protection If the active power distributor reaches its maximum output limit it will switch off This may result from connecting too many devices when the overall output exceeds 3600 W or if the active power distributor has to compensate for excessive differences in voltage due to insufficient power s...

Страница 13: ...gangsspannung an den Steckdosen an Zeigt die Summe der aktuellen Ausgangsleistung in Stufen an Gruppe A B C D Zeigt die aktuelle Gerätetemperatur an Display Das Display ist ausgeschaltet Programming You can adapt the AC A3016 active power distributor to suit your individual needs You can either freely define filters for the four socket groups or switch on the groups individually There are also eig...

Страница 14: ... on page 16 and 17 Auswahl übernehmen und zurück MENU PROGRAMMIEREN EINSTELLUNGEN SPEICHERN MENU GRUNDEINSTELLUNG MENU ENDE MENU GRUPPE A AENDERN GRUPPE B AENDERN GRUPPE C AENDERN GRUPPE A FILTER AENDERN GRUPPE A AUSSCHALTEN GRUPPE A ZURUECK GRUPPE D AENDERN SPEICHERN PRESET ZURUECK FILTER GRUPPE A AUSSCHALTEN FILTER GRUPPE A POWER FILTER GRUPPE A ANALOG FILTER GRUPPE A DIGITAL FILTER GRUPPE A VID...

Страница 15: ...o groups B to D To save these settings follow the instructions on page 16 and 17 MENU PROGRAMMIEREN EINSTELLUNGEN SPEICHERN MENU GRUNDEINSTELLUNG MENU ENDE MENU GRUPPE A AENDERN GRUPPE B AENDERN GRUPPE C AENDERN GRUPPE A FILTER AENDERN GRUPPE A AUSSCHALTEN GRUPPE A ZURUECK Steckdosengruppe Aus Einschalten GRUPPE D AENDERN SPEICHERN PRESET ZURUECK GRUPPE A EINSCHALTEN ...

Страница 16: ...e settings are saved to preset 2 MENU PROGRAMMIEREN EINSTELLUNGEN SPEICHERN MENU GRUNDEINSTELLUNG MENU ENDE MENU GRUPPE A AENDERN GRUPPE B AENDERN GRUPPE C AENDERN SPEICHERN PRESET 1 SPEICHERN PRESET 2 Insgesamt stehen 8 Speicherplätze zur Verfügung Save the settings to the selected preset number The display flashes once to confirm the setting GRUPPE D AENDERN SPEICHERN PRESET ZURUECK SPEICHERN ZU...

Страница 17: ...ed as the start configuration MENU PROGRAMMIEREN EINSTELLUNGEN SPEICHERN MENU GRUNDEINSTELLUNG MENU ENDE MENU IN AKUSTIK REFERENZ AC A3016 5 Calling up stored settings There are a total of eight memory spaces available for storing the current settings of all groups In the example below the settings stored to preset 2 are called up and adopted PRESET 1 PRESET 2 PRESET 8 Preset IN AKUSTIK REFERENZ A...

Страница 18: ... language of AC A3016 can be set as follows MENU PROGRAMMIEREN EINSTELLUNGEN SPEICHERN MENU GRUNDEINSTELLUNG MENU ENDE MENU GRUNDEINSTELLUNG SPRACHE GRUNDEINSTELLUNG RESET GRUNDEINSTELLUNG ZURUECK Auswahl übernehmen und zurück SPRACHE DEUTSCH SPRACHE ENGLISH SPRACHE ZURUECK ...

Страница 19: ...the factory settings RESET JA RESET ZURUECK 4 Reset The AC A3016 is delivered with the following factory settings Menusprache Deutsch Start Set up Gruppe A Ein Filter Power Start Set up Gruppe B Ein Filter Analog Start Set up Gruppe C Ein Filter Digital Start Set up Gruppe D Ein Filter Video The factory settings of the device can be reset as described below However the stored presets 1 to 8 are re...

Страница 20: ...indicator pos 2 is blinking and the fan is running Check the position and ventilation Check the sum of the connected continuous loads diagram 1 page 9 When a connected component is switched on the active power distributor clicks three times then switches off The starting current of the respective component is much too high 100 Amps The active power distributor also switches off after a short perio...

Страница 21: ... Phono Vorstufe C 4A 2 DVD Player EIN ANALOG AUS AUS EIN VIDEO 1 Beamer D 4A 2 CD Player AUS AUS EIN DIGITAL EIN VIDEO Example configuration The table shows an example of multiple uses for the AC A3016 The devices are grouped and filters set here in such a way as to achieve the highest performance with each different application for pure analogue audio digital audio and of course home cinema You c...

Страница 22: ...t 3 EIN AUS FILTER Preset 2 EIN AUS FILTER Preset 1 EIN AUS FILTER Preset 0 EIN AUS Gerät 1 2 1 2 1 2 1 2 Gruppe A B C D Configuration table Device connection In the adjacent table you can plan the grouping and connections for your components which will ensure you can store and later access the best possible AC A3016 configuration for each individual system use ...

Страница 23: ...tions should only be performed by a qualified electrician Screening test Hold the screening tester firmly by the tip and run it along the length of the cable to be tested If the screening tester lights up the cable is not screened Note This only works of course with 230V power cables which are also plugged in switched on Polarity test You can also use the screening tester to test whether lamps and...

Страница 24: ...UAL in akustik GmbH Co KG Untermatten 12 14 D 79282 Ballrechten Dottingen Tel Fax E Mail Web 49 0 7634 5610 0 49 0 7634 5610 80 mailto in akustik com www in akustik com Note All product illustrations are approximate Specifications subject to change without notice ...

Отзывы: