Care
The active power distributor may NOT be cleaned with aggressive or caustic cleaning agents.
Remove dust and dirt with a soft cloth or brush. Please observe the safety instructions.
Troubleshooting
The red stand-by LED (pos. 3) is not lit and the device will not switch on.
Check the mains connection (pos. 4)
Check the plug socket and the corresponding fuse in the mains distribution panel
The green LED indicator (pos. 2) is blinking and the device will not switch on, but
the fan is running.
The device overheated and is still cooling down. Allow it to cool
Check the position and ventilation
Check the sum of the connected continuous loads (diagram 1, page 9).
The active power distributor switches off after operating for a short period, the
green LED indicator (pos. 2) is blinking and the fan is running.
Check the position and ventilation
Check the sum of the connected continuous loads (diagram 1, page 9)
When a connected component is switched on, the active power distributor clicks
three times then switches off.
The starting current of the respective component is much too high ( > 100 Amps))
The active power distributor also switches off after a short period even though
output is minimal.
Check the polarity/phase of the mains plug (see details on page 8 under Connection, point
5)
After switching on the active power distributor, it immediately switches back to
stand-by mode.
The device has malfunctioned and must be handed in for service
.
Technical data
Dimensions:
ca. 435 x 142 x 365m m (LxHxD
Weight:
ca. 20 kg
Temperature range:
+15 bis +30°C
Power consumption:
stand by = 8 VA
on = 80 – 3600VA
Sockets:
4 groups per 2 sockets
Output rating:
group A: max. 16A / 3600 VA
group C-D: max 4A / 920 VA per group
(see details under Power rating on pages 9 + 10)