8. Enter the email address you'd like to receive the email from (must be a valid
address), the address to receive email, and a carbon copy address if desired.
9. Click Write options and parameters.
10. Close the window.
Activate Alarms
1. Click General information, parameters and functional options.
2. Click the Alarms tab.
3. Select the alarms you wish to activate. To activate alarms that are dependent on
probe parameter readings, select "Reading from probe out of range."
4. Under the "Alarm options" heading, select whether to send alarms using SMS (text)
messages when they occur, then select whether to send alarm statuses each time
the Tube sends measurement values. Email alarms require an SMTP server that
allows login without authentication.
5. Enter the number of consecutive times a parameter in Absolute alarm mode can
exceed its threshold before an SMS message is generated. A value of 1 means an
SMS message is generated every time.
6. Enter the number of consecutive times a parameter in Incremental alarm mode can
exceed its threshold before an SMS message is generated. A value of 1 means an
SMS message is generated every time.
7. Enter the maximum number of text messages to be sent for the same Alarm
episode.
8. Enter the maximum number of alarms that can be sent per day.
9. Click Write alarm parameters.
10. Close the window.
Set Probe Reading Schedule
1. Click Frequency of wake-up events.
2. Click Frequency of probe readings and options.
3. Select how often in minutes the Tube reads the probe. A value of 0 means the Tube
never reads the probe, a value of 60 means every hour, and a value of 1440 means
a reading every 24 hours.
4. Select how often the Tube saves the readings. A value of 1 means every reading.
5. Select how often the Tube transmits the readings. A value of 1 means every
reading.
6. Select the significant digits to be included in the data.