IN-ECO, spol. s r.o.
IN-ECO RING BLOWER - User manual
Version 2012.01
5
www.in-eco.eu
>
injuries due to compressed/discharged gas leaks (burns).
Risk of injury caused by hot surface and hot medium!
the INW ring blower/ vacuum pump
can be very hot. The surface temperature of the warmed-up equipment
can exceed 70°C, and in some cases even reach 160°C.
To prevent burns, do not touch the surface of the equipment during operation. Allow the equipment to cool
down after stopping.
If necessary, install suitable protection preventing random contact with the hot equipment (protective mesh,
perforated plate, etc.).
The compressed medium can be very hot.
Protect yourself against:
>
direct contact with the hot equipment or pipe,
>
injuries due to compressed/sucked gas leaks (burns).
Risk of injury caused by falling or overturned loads!
Observe the safety regulations when operating the equipment and transporting the equipment. Use personal
protective equipment. Secure the equipment against unwanted movement, overturning, falling. Do not stand
under lifted loads!
Noise emission
The maximum levels of acoustical noise, or the sound power level respectively, measured according to the
conditions of the relevant standard, are stated for each piece of equipment at www.in-eco.eu. However, after
installing the equipment, the total noise level in the workplace can exceed 85 dB. In this case:
>
designate the zone with an increased noise level,
>
use hearing protection.
3 Use
3.1 G
ENERAL
This manual applies to
the INW ring blower/ vacuum pump
with a side channel, single-stage and multi-stage,
with a single-phase and three-phase motor. It contains safety information, and instructions for handling,
transporting, installation, start-up, operating, maintenance, storage and disposal. The manual must be availa-
ble at the location in which the equipment is used.
INW
the INW ring blower / vacuum pump
are used for producing overpressure/vacuum. For specific technical
parameters, visit www.in-eco.eu, some of which can also be seen on the equipment label. The technical pa-
rameters of the equipment, namely the maximum pressure difference and suction power, stated on the
www.in-eco.eu website and on the label are valid under the following conditions (nominal values):
>
ambient temperature: 25°C,
>
temperature of gases sucked in: 15°C,
>
gas pressure for a blower on the suction branch and for a pump on the discharge branch: 1013 mbar
(abs).
3.2 C
ONDITIONS OF USE
Purpose
The INW ring blower / vacuum pump
are used for compressing or pumping gases, which are not explosive,
flammable, aggressive or poisonous.
The INW ring blower/ vacuum pump
are designated for continuous operation. Maximum number of starts per
hour: 10.