tected against overloading. (The maximum working pressure is usually 7-15% lower than the maximum pres-
sure stated on the product label.)
8.3 M
ANOMETER
Install a manometer for the purpose of fundamental pressure ratio diagnostics.
8.4 B
ACKFLOW VALVE
A backflow valve can be installed to increase the protection of the equipment against the reverse suction of
liquid into the equipment
.
R
ECOMMENDED INSTALLATION OF THE
INW
RING BLOWER
/
VACUUM PUMP WITH ACCESSORIES
:
The diagram of the recommended (single-stage) INW blower/pump with accessories is shown on figures:
1 Blower/pump
2 Air filter
3 Manometer
4 Safety valve
5 Backflow valve
Fig. 4: Blower with accessories
Fig. 5: Pump with accessories
9 W
ASTE DISPOSAL
Valid waste management legal regulations must be observed for proper waste disposal.