![IMV SmartVibro Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/imv/smartvibro-series/smartvibro-series_instruction-manual_2050061019.webp)
-
19
-
VM-4424S/H Instruction Manual
(Compatible with Version 2.16 or later)
4-3. Filter
Change the settings of high-pass (HPF) and low-pass filters (LPF).
Pressing “Set” would bring you to the screen indicated in Fig.4-8.
By touching the triangles on the screen ( or ), you can change the frequency of each
filter.
(Japanese)
(English)
Fig.4-8 Example of Filter Setting
The range of filter is as follows:
Filter
Minimum
Setting
Maximum
Setting
Setting Step
HPF
5Hz
999Hz
1Hz
LPF
100Hz
10000Hz
100Hz
About Filter Setting
(1)
「
Set “LPF setting value” larger than “HPF setting value”.
If “LPF setting value” is smaller than “HPF setting value”, the filter setting
screen cannot be closed. Be sure to set “LPF setting value > HPF setting value”.
(2) Please refer to “Appendix” for filter characteristics.
5 Hz
10.0 kHz
5 Hz
5 Hz
Caution