6.
Installation
6.1
Preparation
1.
Check that the light fitting will be installed in an environment that matches the ambient
temperatures, gas group and temperature class. This data is shown on the light fitting type plate.
WARNING
The installation of the light fitting in an environment that does not match the specified
conditions can result in a dangerous situation.
WARNING
The installation of the light fitting in an environment that does not match the specified
ambient temperatures can have a strong negative effect on the life span of the light
fitting.
2.
Choose the correct type of protection for the light fitting. The protection device needs to
be a fuse or a circuit breaker of at least 4 kA with a C characteristic.
3.
Determine the number of light fittings that can be installed in each group. Consult the following table for
this.
Installation
protection
55 W
85 W
165 W
100-120
VAC/DC
200-277
VAC/DC
100-120
VAC/DC
200-277
VAC/DC
200-277
VAC/DC
B Type, 10 A
15
20
15
20
10
C type, 10 A
15
20
15
20
10
B Type, 16 A
22
30
22
30
16
C type, 16 A
26
35
26
35
16
55 W
85 W
165 W
100-120
VAC/DC
200-277
VAC/DC
100-120
VAC/DC
200-277
VAC/DC
200-277
VAC/DC
Inrush currents
16
12
16
12
24
Peak duration
170 μs
170 μs
170 μs
170 μs
140 μs
When using 30 mA earth leakage switches, provision must be made for a maximum of 30 light fittings on one
switch.
6.2
Assembly
1.
Take the light fitting out of the packaging.
2.
Inspect the light fitting for mechanical damage.
WARNING
The installation of the light fitting in an environment that does not match the specified
conditions can result in a dangerous situation.
WARNING
The installation of the light fitting in an environment that does not match the specified
ambient temperatures can have a strong negative effect on the life span of the light
fitting.
3.
Mount the light fitting.
Ensure there is a reliable connection to the earthing system, both with the external earthing point and
with the connection in the light fitting junction box.
Ensure that the cable gland is suitable for the dimensions of the type of cable that will be connected
and has an IP level of IP66, IP67 or IP68 in conformance with EN 60529, and in case of an explosion
proof lighting fixture, is Ex-e certified according to IEC 60079-7. This is necessary to ensure the IP
protection, and to be suitable for a hazardous environment.
WARNING
Ensure that there is no mechanical load applied to the light fitting during installation.