SECTION 6: TROUBLESHOOTING
IOWA MOLD TOOLING CO., INC.
(641) 923-3711
CAS40PL, CAS40PL-CW, CAS40PLE, CAS40PLE-CW
6.2 TROUBLESHOOTING
GUIDE
MALFUNCTION/FAULT
POSSIBLE CAUSE
CORRECTIVE ACTION
Low air pressure
Air
fi
lters soiled/plugged
Replace air
fi
lter element (
Section 5.4.4
).
Pressure switch setting too low
May need to be replaced or reset; consult Service Depart-
ment for reset instructions.
Air line leak
Inspect and replace hose or tighten connections.
Air consumption exceeds capacity
Check applied demand on supply air.
Faulty compressor valves
Inspect and replace.
Defective air pressure switch / trans-
ducer
Refer to
Section 5.4.2
and
Section 7.7
or
Section 7.8
.
Replace if necessary.
Discharge valve soiled or stuck
Remove and clear, or replace.
Blown head gasket
Replace.
Abnormal pressure
fl
uctuations
Air line leak
Inspect and replace hose or tighten connections.
Pressure switch incorrectly set
May need to be replaced or reset; consult Service Depart-
ment for reset instructions.
Pressure switch faulty
Replace; consult Service Department for reset instructions.
Hydraulic supply problems
Refer to
Compressor runs slow
section of this table.
Pressure relief valve(s) open con-
tinuously
Defective air pressure gauge
Refer to
Section 5.4.2
and
Section 7.5.
Replace if neces-
sary.
Damaged, worn, or leaking valve
Replace valve.
Pressure switch set too high
May need to be replaced or reset; consult Service Depart-
ment for reset instructions.
Compressor cycles too frequently
Air line leak
Inspect and replace hose or tighten connections.
Pressure switch differential setting is too
small
May need to be replaced or reset; consult Service Depart-
ment for reset instructions.
Pressure switch faulty
Replace; consult Service Department for reset instructions.
Excessive moisture in receiver tank
Drain tank; check/drain on more frequent interval to pre-
vent moisture build-up.
Discharge air valve leaking
Replace.
Pressure switch faulty (if it does not
remove power from the solenoid valve)
Replace; consult Service Department for reset instructions.
Compressor will not shut OFF or
unload
Solenoid valve does not operate (no
power to solenoid valve)
Replace solenoid valve; refer to
Section 7.10
or
7.11
.
Air line leak
Inspect and replace hose or tighten connections.
Oil in discharge air
Air intake restricted
Replace air
fi
lter element (
Section 5.4.4
).
Compressor crankshaft over
fi
lled
Drain to correct level.
Compressor crankcase has oil with the
wrong viscosity
Drain crankcase and re
fi
ll with the correct oil (
Section
5.4.3.2
).
Continued on next page