INTRODUCTION

The LD920 features a long life sensor technology that is designed to detect H2/N2 
Tracer Gas mixture.

Our unique digital leak size indicator takes the guesswork out of whether to repair 
a small leak. The digital display is independent from the audio alarm and sensitivity 
level, allowing the precise pinpointing of the leak source. 

When used with the H2/N2 Tracer Gas mixture, the LD920 will detect leak rates 
less than 5 ppm. The 5%H2/ 95%N2 Tracer Gas mixture is consistent with the 
teaching of EMC Directive 2014/30/EU for use with Low GWP Leak Detection 
System Tracer Gas. The LD920 does not require rechargeable batteries. 

FEATURES

•  Unique numeric leak size Indicator

•  Long life, stable sensor

•  H2/N2 sensitivity <5 ppm  

•  Automatic calibration and reset to ambient

•  Visual LED leak alarm near sensor 

•  3 adjustable sensitivity levels

•  Low battery indicator 

•  True mechanical pump

•  Audio mute function 

•  Uses 4 AA alkaline batteries

•  CE Certified 

•  Comfortable Sanoprene grip

•  2-year warranty includes sensor 

•  Made in USA

2

LeakDetectors-LD920-UserManual.indd   2

12/7/16   2:26 PM

Содержание LD920

Страница 1: ...H2 N2 Tracer Gas Leak Detector Detects 5 H2 in 95 Nitrogen Tracer Gas LD920 User Manual Made in U S A LeakDetectors LD920 UserManual indd 1 12 7 16 2 26 PM...

Страница 2: ...m The 5 H2 95 N2 Tracer Gas mixture is consistent with the teaching of EMC Directive 2014 30 EU for use with Low GWP Leak Detection System Tracer Gas The LD920 does not require rechargeable batteries...

Страница 3: ...n 9 5 mm and no faster than 3 in sec 75 mm sec If the detector alarms make smaller sweeps back and forth until the leak source can be pin pointed NOTE The LD920 only responds to changes in leak concen...

Страница 4: ...oximate the size of leak Maximum Approx Leak Size Approx Leak Size Displayed oz yr g yr 1 3 0 1 3 4 6 0 1 to 0 5 3 to 14 7 9 0 5 14 LOW BATTERY INDICATOR Replace the 4 AA Alkaline batteries when the r...

Страница 5: ...xpose the vent hole in the top of the screw cap see fig below 2 Turn on the leak detector and allow the instrument to complete the warm up cycle 3 Place the sensor close to the small hole in the top o...

Страница 6: ...th the raised keyway on sensor socket holder see figure below Note Do not force sensor into socket Misalignment can damage the sensor pins IMPORTANT The instrument s software is designed to alert the...

Страница 7: ...eted The 5 H2 95 N2 Tracer Gas mixture is consistent with the teaching of EMC Directive 2014 30 EU for use with Low GWP Leak Detection System Tracer Gas The LD920 detects the Hydrogen component of the...

Страница 8: ...ls should be returned to the buyer s place of purchase SERVICE TECHNICAL QUESTIONS CALL TOLL FREE 888 467 8665 30333 Emerald Valley Pkwy Glenwillow Ohio 44139 888 467 8665 REPLACEMENT PARTS Item Part...

Отзывы: