Impco ITK-1 Скачать руководство пользователя страница 12

 

April, 2008                                                     IMPCO Technologies Inc.                                            PPI-109-REV. B 
Page 12 of 12                                                      3030 South Susan St. 

Santa Ana, CA 92704 

www.impcotechnologies.com

 

 
 
 
 

WARNING: 

IMPROPER INSTALLATION OR USE OF THIS PRODUCT MAY CAUSE 

SERIOUS INJURY AND/OR PROPERTY DAMAGE. 

 
 

SERVICE TECHNICIANS AND USERS 

SHOULD CAREFULLY READ AND ABIDE BY THE PROVISIONS SET FORTH IN NATIONAL FIRE PROTECTION 
ASSOCIATION PAMPHLET #37 FOR STATIONARY ENGINES, #52 FOR CNG VEHICULAR FUEL SYSTEMS OR #58 FOR 
LPG SYSTEMS. 
 

INSTALLERS 

LPG INSTALLATIONS IN THE UNITED STATES MUST BE DONE IN ACCORDANCE WITH FEDERAL STATE OR LOCAL 
LAW, WHICHEVER IS APPLICABLE AND NATIONAL FIRE PROTECTION ASSOCIATION PAMPHLET #58, STANDARD 
FOR STORAGE AND HANDLING OF LIQUEFIED PETROLEUM GASES TO THE EXTENT THESE STANDARDS ARE NOT 
IN VIOLATION WITH FEDERAL, STATE OR LOCAL LAW. 
 

IN CANADA

 

REFER TO CAN/CGA PROPANE INSTALLATION CODES. 
 

CNG INSTALLATIONS IN THE UNITED STATES

 

MUST RE DONE IN ACCORDANCE WITH FEDERAL STATE OR LOCAL LAW AND NATIONAL FIRE PROTECTION 
ASSOCIATION PAMPHLET #52, COMPRESSED NATURAL GAS (CNG) VEHICULAR FUEL SYSTEMS TO THE EXTENT 
THESE STANDARDS ARE NOT IN VIOLATION WITH FEDERAL, STATE OR LOCAL LAW. 
 

IN CANADA

 

REFER TO CAN/CGA CNG INSTALLATION CODES. 
 

LPG AND/OR NATURAL GAS INSTALLATIONS ON STATIONARY ENGINES 

MUST RE DONE IN ACCORDANCE WITH FEDERAL, STATE OR LOCAL LAW AND NATIONAL FIRE PROTECTION 
ASSOCIATION PAMPHLET #37, STATIONARY COMBUSTION ENGINES AND GAS TURBINE ENGINES, TO THE EXTENT 
THESE STANDARDS ARE NOT IN VIOLATION WITH FEDERAL, STATE OR LOCAL LAW. FAILURE TO ABIDE BY THE 
ABOVE WILL VOID ANY IMPCO WARRANTY ON THE PRODUCTS AND MAY CAUSE SERIES INJURY OR PROPERTY 
DAMAGE. 
 
DUE TO THE INHERENT DANGER OF GASEOUS FUELS THE IMPCO PRODUCTS SHOULD NOT BE INSTALLED OR 
USED BY PERSONS NOT KNOWLEDGEABLE OF THE HAZARDS ASSOCIATED WITH THE USE OF GASEOUS FUELS.

 

 

Содержание ITK-1

Страница 1: ...PPI 109 REV B IMPCO Technologies Inc April 2008 ITK 1 Test Kit User s Manual 3030 South Susan St Page 1 of 12 Santa Ana CA 92704 www impcotechnologies com...

Страница 2: ...April 2008 IMPCO Technologies Inc PPI 109 REV B Figure 1 Page 2 of 12 3030 South Susan St Santa Ana CA 92704 www impcotechnologies com...

Страница 3: ...stributor for instructions ITEM DESCRIPTION QTY USED IMPCO PART NUMBER 1 Bushing Model J 1 B3 26 2 Fitting 1 8 NPT 3 16 HS Nip Brass 1 F4 4 3 Hose 3 16 ID Vacuum Bulk 8 feet H1 11 4 Test Kit Gauge 0 5...

Страница 4: ...ey can be used to measure the difference in pressures between two separate areas or they can be used to measure either positive pressure or negative pressure vacuum TG 005 TG 010 Before using either o...

Страница 5: ...ted insert the provided Allen wrench into the adjusting screw and turn to make adjustments as necessary NOTE The cover must be installed with o ring when in use Pressure will discharge from front of g...

Страница 6: ...e is properly calibrated NOTE If a manometer or a known calibrated gauge is not available make sure the gauge is zeroed and the needle is not indicating a pressure or pinned when sitting idle This met...

Страница 7: ...no obstructions in front of the regulator primary test port P N F4 8 is a 90O adapter for connections where some obstruction may hinder the use of the straight adapter To connect either adapter to th...

Страница 8: ...o the outside hose nipple on differential gauge TG 005 see section B in this chapter for gauge connections Cobra illustrated with F4 4 The F4 8 is similar 7 Open the fuel tank manual valve and test fo...

Страница 9: ...the gauge as a mounting template Locate the hole under the model number of the regulator or lockoff you are using for the other hole To use as secondary lever height gauge Model E With the secondary...

Страница 10: ...J bushing is used in conjunction with either the F4 4 or F4 8 pressure test adapter for performing a secondary pressure test on a Model J regulator converter To perform the test remove the NPT plug f...

Страница 11: ...ttings left Both the special bleed plug and brass fittings are included in IMPCO Test Kits ITK 1 and ITK 4 2 Attach a 100 psi air pressure hose to the regulator INLET fitting Connect a water column ga...

Страница 12: ...A REFER TO CAN CGA PROPANE INSTALLATION CODES CNG INSTALLATIONS IN THE UNITED STATES MUST RE DONE IN ACCORDANCE WITH FEDERAL STATE OR LOCAL LAW AND NATIONAL FIRE PROTECTION ASSOCIATION PAMPHLET 52 COM...

Отзывы: