Impco ITK-1 Скачать руководство пользователя страница 10

 

April, 2008                                                     IMPCO Technologies Inc.                                            PPI-109-REV. B 

 

 Model 

L: 

With the secondary chamber cover off, lay the gauge on the regulator body with the secondary 
lever inside the slot labeled “L” as illustrated.  The gauge should just contact the secondary 
lever without being lifted from the body.  Make any necessary adjustments by removing and 
carefully bending the secondary lever. 
 
NOTE: 
Bending the lever in place may result in damage to the seat. 
 

 

Model “L” Regulator 

 

E.  Model “J” Bushing: 

The Model “J” bushing is used in conjunction with either the F4-4 or F4-8 pressure test adapter for 
performing a secondary pressure test on a Model “J” regulator/converter.  To perform the test, 
remove the ½” NPT plug from the unused vapor fuel outlet.  Apply a small amount of Loctite

TM

 567 

or equivalent thread sealant on the bushing threads and install the bushing in the outlet.  Then, 
apply some of the sealant onto the F4-4 or F4-8 pressure adapter and install it into the bushing.  
Connect the 3/16” vacuum hose to the adapter and the other end of the hose to the proper pressure 
gauge nipple (depending on fuel type). 

Page 10 of 12                                                      3030 South Susan St. 

Santa Ana, CA 92704 

www.impcotechnologies.com

 

Содержание ITK-1

Страница 1: ...PPI 109 REV B IMPCO Technologies Inc April 2008 ITK 1 Test Kit User s Manual 3030 South Susan St Page 1 of 12 Santa Ana CA 92704 www impcotechnologies com...

Страница 2: ...April 2008 IMPCO Technologies Inc PPI 109 REV B Figure 1 Page 2 of 12 3030 South Susan St Santa Ana CA 92704 www impcotechnologies com...

Страница 3: ...stributor for instructions ITEM DESCRIPTION QTY USED IMPCO PART NUMBER 1 Bushing Model J 1 B3 26 2 Fitting 1 8 NPT 3 16 HS Nip Brass 1 F4 4 3 Hose 3 16 ID Vacuum Bulk 8 feet H1 11 4 Test Kit Gauge 0 5...

Страница 4: ...ey can be used to measure the difference in pressures between two separate areas or they can be used to measure either positive pressure or negative pressure vacuum TG 005 TG 010 Before using either o...

Страница 5: ...ted insert the provided Allen wrench into the adjusting screw and turn to make adjustments as necessary NOTE The cover must be installed with o ring when in use Pressure will discharge from front of g...

Страница 6: ...e is properly calibrated NOTE If a manometer or a known calibrated gauge is not available make sure the gauge is zeroed and the needle is not indicating a pressure or pinned when sitting idle This met...

Страница 7: ...no obstructions in front of the regulator primary test port P N F4 8 is a 90O adapter for connections where some obstruction may hinder the use of the straight adapter To connect either adapter to th...

Страница 8: ...o the outside hose nipple on differential gauge TG 005 see section B in this chapter for gauge connections Cobra illustrated with F4 4 The F4 8 is similar 7 Open the fuel tank manual valve and test fo...

Страница 9: ...the gauge as a mounting template Locate the hole under the model number of the regulator or lockoff you are using for the other hole To use as secondary lever height gauge Model E With the secondary...

Страница 10: ...J bushing is used in conjunction with either the F4 4 or F4 8 pressure test adapter for performing a secondary pressure test on a Model J regulator converter To perform the test remove the NPT plug f...

Страница 11: ...ttings left Both the special bleed plug and brass fittings are included in IMPCO Test Kits ITK 1 and ITK 4 2 Attach a 100 psi air pressure hose to the regulator INLET fitting Connect a water column ga...

Страница 12: ...A REFER TO CAN CGA PROPANE INSTALLATION CODES CNG INSTALLATIONS IN THE UNITED STATES MUST RE DONE IN ACCORDANCE WITH FEDERAL STATE OR LOCAL LAW AND NATIONAL FIRE PROTECTION ASSOCIATION PAMPHLET 52 COM...

Отзывы: