7.1.4 Auto zero range
•
The auto-zero will automatically set the scale to zero when the
displayed weight is almost near zero. This helps to make sure that
the scale is measuring weight from an accurate zero starting point.
•
The Auto zero value can be set to 0.5, 1, 2 or 4 scale divisions. The
normal setting is 1 scale division. The display will show “
”.
•
Press the [Tare/ ] key to change the value.
•
Press the [Zero/Enter] key to store the changed setting.
7.1.5 Selectable unit of weight displayed
•
The scales are normally set to display in kilograms, however they
will show the weight in grams, if enabled.
•
The display will show “
” or “
”.
•
Press [Tare/ ] to change the setting between or
•
Press the [Zero/Enter] key to store the changed setting.
When the scales are set to display in other units of weight the accumulation
function is still keeping the weight in kilograms (or pounds for the CBWa
series) in memory and will use the base weighing unit when printing over the
RS-232 interface.
7.1.6 Setting of the check weighing alarm
•
The display will show “
” where “ ” is a digit from to .
will set the buzzer to off when check weighing
will set the buzzer to on when the OK symbol is on
will set the buzzer to on when the weight is outside
the OK symbol limit
•
To change this digit press the [Tare/ ] key.
CBWa Scales only:
The CBWa scales can change units from kilograms to grams, pounds or
pounds/ounces immediately if they are enabled as in the step above. This also allows
the scales to be calibrated in either kilograms or pounds and all memory accumulations
are in either kilograms or pounds as last selected.