34
Part. A
Part. B
8
7
11
10
A
A
A
A
2
B
B
9
4
4
3
6
8
7
8
5
5
1
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
- Check visually that the safety and control
devices have not been tampered with and/or
shorted, in particular:
- temperature safety thermostat;
- Check the condition and integrity of the
electrical system and in particular:
- electrical power cables must be inside the
fairleads;
- there must be no traces of blackening or
burning.
N.B.:
on occasion of periodical maintenance of
the appliance it is appropriate also to check and
perform maintenance on the heating system, in
compliance with that indicated by the regulations
in force.
3.17 CASING REMOVAL.
To facilitate boiler maintenance the casing can
be completely removed as follows:
- disassemble the front (1) of the boiler by
loosening screw (2) by 1/4 turn, push the front
upwards while pulling downwards at the same
time to release from the lateral (3) and upper
(4) hooks;
- undo the 2 screws (5) of the control panel (6);
- tilt the control panel (6) pulling it towards
yourself ( figure);
Fig. 3-5
- remove the sides (7) loosening the screws (8),
push slightly upwards in a way to release the
side from the seat (9) and pull towards yourself
(see figure);
- remove the lower grid (10) removing it from
the two seats (11) by inserting a screwdriver
into the relevant seat marked on the grid and
using it as a lever as represented in the figure.