2.6 FAULT AND ANOMALY SIGNALS.
The Victrix Superior TOP 32 X E boiler signals
any anomalies by the flashing symbol (5) along
with the “ERRxx” indication on the indicator
(6) where “xx” corresponds to the error code
described in the following table. On any remote
control the error code will be displayed by means
of the same numerical code number represented
according to the following example (e.g. CAR
V2
= Exx, Super CAR = ERR>xx).
Anomaly signalled
Error
code
No ignition block
01
Safety thermostat block (over-
heating), flame control anomaly
02
Flue safety thermostat block
03
Contacts resistance block
04
Flow probe anomaly
05
Maximum No of resets.
08
Insufficient system pressure
10
Storage tank probe anomaly
12
Configuration error
15
Fan anomaly
16
Parasite flame block
20
Return probe anomaly
23
Push button control panel anomaly
24
Block due to flue gas temperature
gradient intervention
25
Insufficient circulation
27
Flue probe anomaly
29
Loss of remote control
communication
31
Low power supply voltage
37
Loss of flame signal
38
ΔT high
45
Burner power limitation
47
High temperature block on return
probe
49
Attention:
the error codes 31 to 38 are not shown
on the CAR
V2
and Super CAR display, general
code 22 is displayed in its place.
Attention:
The anomaly can be reset up to 5
successive times, after which the function in
inhibited for at least one hour. One attempt is
gained every hour for a maximum of 5 attempts.
By switching the appliance off and on again, the
5 attempts are re-acquired.
Ignition block.
The boiler ignites automatically
with each demand for room central heating or
hot water production. If this does not occur
within 10 seconds, the boiler remains in
stand-by for 30 seconds; try again and if the
second attempt fails it will go into “ignition
block” (ERR01). To eliminate “ignition block”
the Reset button "C" must be pressed. On
commissioning or after extended inactivity it
may be necessary to eliminate the “ignition
block”. If this phenomenon occurs frequently,
contact a qualified technician for assistance
(e.g. Immergas After-Sales Technical Assistance
Service).
Safety thermostat block (over-heating).
During operation, if a fault causes excessive
overheating internally, or an anomaly occurs in
the flame control section, an overheating block
is triggered in the boiler (ERR02). To eliminate
“over-temperature block” the Reset button "C"
must be pressed. If this phenomenon occurs
frequently, contact a qualified technician for
assistance (e.g. Immergas After-Sales Technical
Assistance Service).
Flue safety thermostat block.
This occurs in
the case of partial internal obstruction (due to
the presence of lime scale or slurry) or external
blocking should occur (combustion residues)
to the condensation module. To eliminate the
“flue thermostat block” the Reset button “C”
must be pressed. Call an authorised technician
to remove the obstructions (e.g. Immergas After-
sales Service).
Contacts resistance block.
To eliminate the
“flue thermostat block” the Reset button “C”
must be pressed. Call an authorised technician
to remove the obstructions (e.g. Immergas
After-sales Service). The boiler does not start
and a technician must be called (e.g. Immergas
After-Sales Service).
Flow probe anomaly.
If the board detects an
anomaly on the system NTC delivery probe, the
boiler will not start; contact a qualified technician
for assistance (e.g. Immergas After-Sales Service).
Maximum No of resets.
Available number of
resets already made.
Insufficient system pressure.
Water pressure
inside the central heating system that is sufficient
to guarantee the correct functioning of the boiler
is not detected. Check on the boiler manomater
(1) that the system pressure is between 1÷1.2
bar and restore the correct pressure if necessary.
Storage tank probe anomaly.
If the board detects
an anomaly on the storage tank probe, the boiler
cannot produce domestic hot water. A qualified
technician must be called (e.g. Immergas After-
Sales Technical Assistance Service).
Configuration error.
If the board detects an
anomaly or in congruency on the electric wiring,
the boiler will not start. If normal conditions are
restored the boiler restarts without having to be
reset. If this anomaly persists, contact a qualified
technician for assistance (e.g. Immergas After-
Sales Service).
Fan anomaly.
This occurs if the fan has a
mechanical or electrical fault. To eliminate
the “fan anomaly” the Reset button "C" must
be pressed. If this anomaly persists, contact a
qualified technician for assistance (e.g. Immergas
After-Sales Service).
Parasite flame block.
This occurs in case of a
leak on the detection circuit or anomaly in the
flame control unit. The boiler can be reset in
order to allow a new ignition attempt. If the boiler
does not start, contact a qualified technician for
assistance (e.g. Immergas After-Sales Service).
Return probe anomaly.
If the board detects an
anomaly on the system return NTC probe, the
boiler will not start; contact a qualified technician
for assistance (e.g. Immergas After-Sales Techni-
cal Assistance Service).
Push button control panel anomaly.
This occurs
when the P.C.B. detects an anomaly on the push
button control panel. If normal conditions are
restored the boiler restarts without having to be
reset. If this anomaly persists, contact a qualified
technician for assistance (e.g. Immergas After-
Sales Service).
Block due to flue gas temperature gradient
intervention.
If the board detects a rapid
increase of flue gas temperature probably due
to a blocked pump or lack of water in the heat
exchanger, the boiler blocks due to the flue gas
temperature gradient intervention. To eliminate
it, the Reset button (C) must be pressed. If
this phenomenon occurs frequently, contact a
qualified technician for assistance (e.g. Immergas
After-Sales Technical Assistance Service).
Insufficient circulation.
This occurs if there
is overheating in the boiler due to insufficient
water circulating in the primary circuit; the
causes can be:
- low system circulation; check that no shut-off
devices are closed on the heating circuit and
that the system is free of air (deaerated);
- circulating pump blocked; free the circulating
pump.
If this phenomenon occurs frequently, contact a
qualified technician for assistance (e.g. Immergas
After-Sales Technical Assistance Service).
Flue probe anomaly.
If the board detects an
anomaly on the flue probe, the boiler will not
start; contact a qualified technician for assistance
(e.g. Immergas After-Sales Technical Assistance
Service).
Loss of remote control communication.
This
occurs in the case of connection to a remote
control that is not compatible or if there is a
loss of communication between the boiler and
CAR remote control
V2
or Super CAR remote
control. Try the connection procedure again by
turning the boiler off and then back on again. If
the Remote Control is still not detected on re-
starting the boiler will switch to local operating
mode, i.e. using the controls on the boiler
itself. In this case the boiler cannot activate the
“Central heating” function. To make the boiler
function in “Central heating” mode, activate the
“P33” function present inside the “M3” menu.
If this phenomenon occurs frequently, contact a
qualified technician for assistance (e.g. Immergas
After-Sales Technical Assistance Service).
Low power supply voltage
This occurs when
the power supply voltage is lower than the
allowed limits for the correct functioning of
the boiler. If normal conditions are restored,
the boiler re-starts without having to be reset.
If this phenomenon occurs frequently, contact a
qualified technician for assistance (e.g. Immergas
After-Sales Technical Assistance Service).
Содержание Victrix Superior Series
Страница 1: ...VICTRIX Superior TOP 32 X E IE Instruction and warning book 1 036645ENG ...
Страница 2: ......
Страница 38: ......
Страница 39: ......