5
STVZSkW ed 09/08
VICTRIX ZEUS Superior kW I
Technical Documentation
Technical Documentation
The hot water used for central heating and domestic hot water
is produced via a primary and a secondary circuit (DHW)
which are affected according to necessity.
VICTRIX ZEUS Superior kW I hydraulic diagram.
Key:
1 - Condensate drain trap
2 - Stainless steel coil for storage tank
3 - Magnesium anode
4 - Stainless steel storage tank
5 - Gas valve
6 - Gas valve outlet pressure point (P3)
7 - Air/gas Venturi manifold
8 - Fan
9 - Gas nozzle
10 - Detection electrode
11 - Flue safety thermostat
12 - Air intake pipe
13 - Condensation module
14 - Manual air vent valve
15 - Flue hood
16 - Air sample point
17 - ∆p gas pressure point
18 - Flue sample point
19 - Flow probe
20 - Safety thermostat
21 - Burner
22 - Ignition electrodes
23 - Condensation module cover
24 - Venturi negative sign (P2)
25 - Venturi positive sign (P2)
26 - Return probe
27 - System expansion vessel
28 - Boiler pump
29 - Adjustable by-pass
30 - System pressure switch
31 - System draining valve
32 - 3-way valve (motorised)
33 - Domestic hot water probe
34 - 3 bar safety valve
35 - System filling valve
36 - Domestic hot water expansion vessel
37 - 8 bar safety valve
38 - Cold water inlet non-return valve
39 - Storage tank drain cock
G - Gas supply
SC - Condensate drain (minimum internal diame-
ter Ø 13 mm)
AC - Domestic hot water outlet
AF - Domestic cold water inlet
R - System return
M - System flow
Содержание VICTRIX Superior 32 kW X