background image

4

1-3

1-4

B

A

A

INS

T

ALLER

US

ER

 MAINTEN

AN

CE TECHNI

CI

AN

Hydraulic circuit resistance.

H

ea

d (kP

a)

Flow rate (l/h)

H

ea

d (m H

2

O)

  A  -  Storage tank unit hydraulic 

circuit resistance

1.4  ELECTRICAL CONNECTION:

The storage tank has an IPX0D protection rating 
for the entire appliance. Electrical safety of the 
appliance  is  reached  only  when  it  is  correctly 
connected  to  an  efficient  earthing  system  as 
specified by current safety standards.

Important:

  Immergas  S.p.A.  declines  any 

responsibility  for  damage  or  physical  injury 
caused by failure to connect the storage tank unit 
to an efficient earth system or failure to comply 
with the reference standards.

Also  ensure  that  the  electrical  installation 
corresponds  to  maximum  absorbed  power 
specifications  as  shown  on  the  storage  tank 
data-plate.
The storage tank unit is supplied complete with 
an “X” type power cable without plug.

Solar collector probe connection.

Connect  the  solar  collector  probe  to  pins  45 
and  46  onto  the  terminal  board  (Fig.1-5  part. 
17) present inside the storage tank unit, paying 
attention  to  eliminate  the  resistance  R15  as 
indicated in the wiring diagram.

Storage tank connection to the boiler.

Connect  the  storage  tank  to  the  boiler  as 
indicated  in  the  wiring  diagram,  using  a  cable 
(not present) to connect clamps 36 and 37 to the 
boiler and to the storage tank.

Storage tank unit electric connection.

The  power  supply  cable  must  be  connected  to 
a  230V  ±10%  /  50Hz  mains  supply  respecting 
L-N  polarity  and  earth  connection 

.  This 

network  must  also  have  an  omnipolar  circuit 
breaker  with  class  III  over-voltage  category. 
When replacing the power supply cable, contact 
a qualified technician (e.g. the Immergas After-
Sales Technical Assistance Service).

For  the  main  power  supply  to  the  appliance, 
never use adapters, multiple sockets or extension 
leads.

Solar  collector  return  probe  connection 
(optional).

Connect the solar collector return probe to pins 
8 and 7 on the terminal board present inside the 
storage tank unit.

Important:

 after the connections have bee made, 

the new system layout must be set on the solar 
control unit as follows:

-  press the “i” key for about 10 seconds;

-  use  the  scrolling  keys  to  find  parameter  27 

(system configuration);

-  press the “i” key for about 2 seconds.

-  on  enter ing  p arameter  27,  f ind  t hat 

configuration 1 is set; use the scrolling keys to 
select configuration 2.

-  press the “i” key to confirm the configuration 

selected.

1.5  SYSTEM FILLING.

Once the storage tank has been connected, fill 
the system via the boiler filling valve. Filling is 
performed at low speed to ensure release of air 
bubbles in the water via the boiler and central 
heating system vents.
Close the filling valve when the boiler manometer 
pointer  indicates  approx.  1.2  bar  (see  boiler 
instruction book).

1.6  DOMESTIC HOT WATER STORAGE 

TANK UNIT.

The  storage  tank  unit  must  be  connected  to  a 
boiler. It contains large coiled stainless steel heat 
exchanger pipes, which allow to notably reduce 
hot  water  production  times.  This  storage  tank 
unit, manufactured with stainless steel casing and 
bottoms, guarantees long duration through time.

The assembly concepts and welding (T.I.G.) are 
implemented to the minimum detail to ensure 
maximum reliability.
The  upper  inspection  flange  ensures  practical 
control of the storage tank unit and the coil heat 
exchanger pipe and easy internal cleaning.
The  DHW  couplings  are  positioned  on  the  lid 
of  the  flange  (cold  inlet  and  hot  outlet).  The 
Magnesium  Anode  holder  cap  including  the 
same, supplied as per standard for the internal 
protection  of  the  storage  tank  from  possible 
corrosion, is found on the side of the storage tank.

N.B.:

  every  year  a  skilled  technician  (e.g. 

Immergas  Authorised  After-sales  Service), 
must  check  the  efficiency  of  the  storage  tank 
unit Magnesium Anode. The storage tank unit 
is prepared for introduction of the domestic hot 
water pump fitting.

1.7  HYDRAULIC CIRCUIT RESISTANCE.

In order to guarantee sufficient DHW flow rate, 
it is important to consider the resistance of the 
storage tank hydraulic circuit to be coupled to 
the boiler. (Fig. 1-3). For correct connection of 
the storage tank unit to Immergas boilers, see the 
boiler instruction book.

1.8  CIRCULATION PUMP.

The storage tank unit is supplied with a built-in 
circulation pump with 3-position electric speed 
control.  With  the  circulation  pump  on  first 
speed  it  is  probable  that  there  is  not  sufficient 
circulation. The circulation pump is already fitted 
with a capacitor.

Pump  release.

  If,  after  a  prolonged  period  of 

inactivity,  the  circulation  pump  is  blocked, 
unscrew the front cap and turn the motor shaft 
using a screwdriver. During this operation, avoid 
damage to the motor.

Circulation group available head.

H

ea

d (m H

2

O)

H

ea

d (kP

a)

Flow rate (l/h)

  A  =  Head available to the pump unit at third speed
  B  =  Head available to the pump unit at second speed

Содержание UB INOX SOLAR 200-2

Страница 1: ...UB INOX Solar 200 2 STORAGE TANK UNIT Instruction booklet and warning IE 1 033447ENG ...

Страница 2: ...on compliance of technical laws in force standards or instructions contained in this book or however supplied by the manufacturer the manufacturer is excluded from any contractual and extra contractual liability for any damage and the appliance warranty is invalidated For further information regarding legislative and statutory provisions relative to the installation consult the Immergas site at th...

Страница 3: ...designed for floor installation they must be used for the storage of domestic hot water and similar purposes They have not be designed for wall installation Important these units are used to store water at a temperature below boiling point at atmospheric pressure They must be connected to a boiler and to aDHWwater distribution network They must be installed in rooms where the temperature cannot fa...

Страница 4: ...use the scrolling keys to select configuration 2 press the i key to confirm the configuration selected 1 5 SYSTEM FILLING Once the storage tank has been connected fill the system via the boiler filling valve Filling is performed at low speed to ensure release of air bubbles in the water via the boiler and central heating system vents Closethefillingvalvewhentheboilermanometer pointer indicates app...

Страница 5: ... can also depend on the value set on the boiler however theDHWtemperatureupperlimitvalueisalways determined by the position of the mixing valve knob position 1 42 C 2 48 C 3 54 C 4 60 C as per standard the values indicated refer to a storage tank with water at 70 C Any release of the three way mixing valve If after a long period of inactivity the three way mixing valve is blocked it is necessary t...

Страница 6: ...ound on the ground floor and the solar collector is found on the roof at a hypothetical height of 6 m the distance to be calculated is 6 m x 0 1 bar 0 6 bar therefore the expansion vessel must be charged to 2 0 6 2 6 bar Hydraulic unit safety valve There is a safety valve present on the hydraulic unit that protects the system from an excessive increase in pressure This valve intervenes by discharg...

Страница 7: ...to previous menu Parameter next value selection Parameter previous value selection Access to the parameters system info value confirmation Functions programming Access to the board parameters menu is given through the buttons present on the control unit To access the parameters menu and modify a value necessary Press the key once and hold for 10 seconds access to the menu Scroll to the parameter t...

Страница 8: ...re C 90 160 C 140 C 18 Tank Maximum Temperature C 70 95 C 80 C 19 Value of the temperature differential between the solar collector maximum temperature PAR 17 and the solar collector temperature above which the solar collector cooling function activates Solar collector cooling function 0 Function deactivated 0 20 C 0 20 Diverter functioning 0 Off 1 Auto 2 On 0 2 1 21 Value of the Δ flow return tem...

Страница 9: ...or T solar collector return T PAR 21 Solar collector anti freeze function The Solar Pump activates when Solar collector T PAR 23 The board will not deactivate the solar pump until Solar collector T PAR 23 1 C Important the default anti freeze function is deactivated PAR 23 0 Solar pump anti block function After 24 hours of inactivity the system pumps are activated for 3 seconds Diverter valve anti...

Страница 10: ...storage tank use the special valve in the lower part of the storage tank Fig 1 5 part 8 Before draining ensure that the DHW inlet valve is closed 2 3 CASE CLEANING Use damp cloths and neutral detergent to clean the storage tank casing Never use abrasive or powder detergents 2 4 DECOMMISSIONING In the event of permanent shutdown of the storage tank contact professional staff for the relative operat...

Страница 11: ...0 Cold water inlet filter 11 One way valve OV 15 Optional 12 Cold water inlet cock 13 One way valve 14 6 bar safety valve 15 Shut off valve with thermometer 16 Solar expansion vessel 17 Solar pump 18 Flow meter 19 Domestic hot water probe 20 DHW inlet probe 21 Stainless steel coil that can be coupled to solar panels 22 Solar system draining valve 23 Solar panels probe AC DHW outlet RU Return from ...

Страница 12: ...k Magnesium anode Check the state of the internal coil Check the presence of any slurry deposits on the bottom of the storage tank Key A12 Solar management control unit B2 Domestic hot water probe NTC B11 Solar collector probe PT1000 B12 Solar storage tank probe NTC B19 Domestic inhibition probe NTC B20 Solar collector return probe PT1000 Optional M6 Solar circuit pump R8 Storage tank function inh...

Страница 13: ...de maximum temperature C 99 Domestic hot water expansion vessel l 8 Dispersions kW 24h 3 42 Coil thickness mm 0 8 Solar coil length mm 6 500 CH coil length mm 10 700 Solar coil exchange surface m2 0 41 CH coil exchange surface m2 0 67 Solar coil capacity l 1 73 CH coil capacity l 2 84 CH solar primary fluid flow rate coil l h 1 140 1 140 Coil head loss at 1000 l h kPa m H2 O 12 3 1 25 Central heat...

Страница 14: ......

Страница 15: ......

Страница 16: ...mmergas com Immergas S p A 42041 Brescello RE Italy T 39 0522 689011 F 39 0522 680617 This instruction booklet is made of ecological paper Cod 1 033447ENG rev ST 000709 000 02 2014 Inglese per IRLANDA IE ...

Отзывы: