It is just as important that the intake grids and exhaust
terminals are not obstructed.
Keep all flammable objects away from the appliance
(paper, rags, plastic, polystyrene, etc.).
The minimum distance for exhaust pipes from flam-
mable materials must be at least 25 cm.
Do not put household appliances under the boiler as they could
be damaged if the safety valve trips or if the hydraulic fittings
leak. Otherwise, the manufacturer cannot be held liable for any
damage to the household appliances.
For the aforementioned reasons, we recommend not placing
furnishings, furniture, etc. under the boiler.
In the event of malfunctions, faults or incorrect operation, turn
the appliance off and contact an authorised company (e.g. the
Authorised Technical Assistance Centre, which has specifically
trained staff and original spare parts). Do not attempt to modify
or repair the appliance alone.
Any modification to the appliance that is not explicitly indicated
in this section of the booklet is forbidden.
Installation regulations.
- Installation of these boilers in bedro-
oms, studio flats and bathrooms, or in
premises where there are wood fired heaters
(or solid fuel heaters in general) and in premi-
ses next to or connected to them, is subject to
the regulatory/legislative provisions in force
in the country.
- Installation of gas appliances, flue exhaust
pipes and combustion air intake pipes is for-
bidden in places with a fire risk (for example:
garages, closed parking stalls), and in poten-
tially dangerous places.
- Installation is prohibited on the verti-
cal projection of the cooking surface.
- Installation is forbidden in places/
rooms that constitute public areas of apart-
ment buildings, internal stairways or other
escape routes (e.g. floor landings, entrance
halls, etc.).
- Installation is also forbidden in places/rooms
that constitute public areas of apartment
buildings such as cellars, entrance halls, at-
tics, lofts, unless otherwise provided for by
local regulations in force.
- These boilers are not suitable for installation
on walls made of combustible material.
- Type B open chamber boilers must not
be installed in places where commercial,
artisan or industrial activities take place,
which use products that may develop volatile
vapours or substances (e.g. acid vapours,
glues, paints, solvents, combustibles, etc.),
as well as dusts (e.g. dust deriving from the
working of wood, coal fines, cement, etc.),
which may be damaging for the components
of the appliance and jeopardise functioning.
- They must also be installed in an environ-
ment in which the temperature cannot fall
below 0°C. They must not be exposed to
atmospheric agents.
- This natural draught boiler can be connected
only to a multiple branched flue served by
a variety of users in existing buildings. The
boiler takes the combustion air directly from
the installation room and is equipped with
draught-breaker/anti-wind device. Due to
lower efficiency, any other use of this boiler
must be avoided as it would lead to greater
consumption and higher operating costs
.