Error
Code
Anomaly signalled
Cause
Boiler status / Solution
38
Loss of flame signal
This occurs when the boiler is ignited correctly and the burner
flame switches off unexpectedly; a new attempt at ignition is
performed and if normal conditions are restored, the boiler
does not have to be reset.
If normal conditions are restored the boiler
restarts without having to be reset (1) (2)
43
Block due to loss of
flame signal
This occurs if the ''Flame signal loss'' error occurs many times
in a row within a preset period (38).
Press the Reset button, before restarting,
the boiler will run a post-ventilation
cycle. (1)
44
Block due to exceeding
storage tank
maximum opening time
close to gas valve
This occurs if the gas valve remains open for longer than re-
quired for normal operation, without
the boiler switching on.
Press the Reset button (1)
44
Block for maximum
time, partial gas valve
opening
This occurs if the gas valve remains open for longer than
required for normal operation, without the boiler switch-
ing on.
Press the Reset button (1).
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Technical After-Sales Service)
(2) The anomaly can only be verified in the list of errors in the “Information” menu