30
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
- Flue temperature values refer to an air inlet
temperature of 15°C.
- The data relevant to domestic hot water
performance refers to a dynamic inlet pressure
of 2 bar and an inlet temperature of 15°C; the
values are measured directly at the boiler outlet
considering that to obtain the data declared
mixing with cold water is necessary.
- The max. sound level emitted during boiler
operation is < 55dBA. The sound level value is
referred to semianechoic chamber tests with
boiler operating at max. heat output, with
extension of flue gas exhaust system according
to product standards.
- (*) Specific capacity “D”: domestic hot water
flow rate corresponding to an average increase
of 30K, which the boiler can supply in two suc-
cessive withdrawals.
- (**) When the boiler is connected to an external
cylinder.
3.20 TECHNICAL DATA.
FAN POWER: 30W
Nominal heat input
kW (kcal/h)
25.6 (22051)
(**) DHW minimum heat input
kW (kcal/h)
8.3 (7117)
CH minimum heat input
kW (kcal/h)
10.5 (9057)
Nominal heat output (useful)
kW (kcal/h)
24.0 (20640)
(**) DHW minimum heat output (useful)
kW (kcal/h)
7.2 (6192)
CH minimum heat output (useful)
kW (kcal/h)
9.3 (7998)
Efficiency at nominal heat output
%
93.6
Efficiency at 30% nominal heat output load
%
90.3
Heat loss at case with burner On/Off
%
0.80 / 0.60
Heat loss at flue with burner On/Off
%
5.60 / 0.06
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature
°C
35 - 85
System expansion vessel total volume
l
4.0
Expansion vessel factory-set pressure
bar
1
Water content in generator
l
2.5
Total head available with 1000 l/h flow rate
kPa (m H
2
O)
24.52 (2.5)
(**) Hot water production useful heat output
kW (kcal/h)
24.0 (20640)
(**) Domestic hot water adjustable temperature
°C
30 - 60
(**) Domestic hot water circuit flow limiter at 2 bar
l/min
7.1
(**) Min. pressure (dynamic) domestic hot water circuit
bar
0.3
(**) Domestic hot water circuit max. working pressure
bar
10
(**) Minimum D.H.W. flow rate
l/min
1.5
(*) Specific capacity “D” UB Immergas 80 l (∆T 30°C) according to EN 625
l/min
20.7
(*) Specific capacity “D” UB Immergas 105 l (∆T 30°C) according to EN 625
l/min
24.4
(*) Specific capacity “D” UB Immergas 120 l (∆T 30°C) according to EN 625
l/min
26.7
(*) Specific capacity “D” UB Immergas 200 l (∆T 30°C) according to EN 625
l/min
35.1
(**) Drawing capacity in continuous duty with UB Immergas (∆T 30°C)
l/min
11.1
Weight of full boiler
kg
33.9
Weight of empty boiler
kg
31.4
Electrical connection
V/Hz
230/50
Power input
A
0.66
Installed electric power
W
130
Pump consumption
W
87.0
Fan consumption
W
35.0
Equipment electrical system protection
-
IPX5D
NO
X
class
-
3
Weighted NO
X
mg/kWh
138
Weighted CO
mg/kWh
95
Type of appliance
C12 / C32 / C42 / C52 / C82 / B22 / B32
Category
II2H3+
Содержание MINI NIKE X 24 3 E
Страница 1: ...MINI EOLO X 24 3 E Instruction and recommendation booklet IE 1 038775ENG ...
Страница 2: ......
Страница 28: ...28 3 5 4 4 5 6 6 d d c INSTALLER USER MAINTENANCE TECHNICIAN ...
Страница 33: ......
Страница 34: ......
Страница 35: ......