1.12 SEPARATOR KIT INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
This kit allows air to come in from outside
the building and the exhaust to exit from the
chimney or flue through divided flue exhaust
and air intake pipes. Combustion products are
expelled from pipe (S). The required amount of
air is taken in through pipe (A) for combustion.
The intake pipe (A) can be installed either on the
right or left hand side of the central exhaust pipe
(S). Both ducts can be routed in any direction.
•
Separator kit Ø 80/80.
Kit assembly (Fig. 1-22):
install the flange (4) on the central hole of the
boiler, interposing the gasket (1) and tighten
with the flat-tipped hex screws included in the
kit. Remove the flat flange present in the lateral
hole with respect to the central one (according
to needs) and replace it with the flange (3),
positioning the gasket (2) already present in
the boiler and tighten using the supplied self-
threading screws. Fit the male end (smooth) to
the bends (5) in the female end of the flanges
(3 and 4). Fit the intake terminal (6) with the
male section (smooth) in the female section of
the bend (5) up to the stop, ensuring that the
internal and external wall sealing plates are
fitted. Fit the exhaust pipe (9) with the male end
(smooth) to the female end of the bend (5) up
to the stop; making sure that the internal wall
sealing plate has been fitted, this will ensure
sealing and joining of the elements making up
the kit.
• Installation clearances. Figure 1-23 gives the
min. installation space dimensions of the
Ø 80/80 separator terminal kit in limited
conditions.
• Figure 1-24 shows the configuration with
vertical exhaust and horizontal intake.
• Extensions for separator kit Ø 80/80. The max.
vertical linear length (without bends) usable
for Ø 80 intake and exhaust pipes is 41 metres
of which 40 intake and 1 exhaust. This total
The kit includes:
N°1 - Exhaust gasket (1)
N°1 - Female intake flange (3)
N°1 - Flange gasket (2)
N°1 - Female exhaust flange (4)
N°2 - 90° bend Ø 80 (5)
N°1 - Intake terminal Ø 80 (6)
N°2 - Internal wall sealing plates (7)
N°1 - External wall sealing plate (8)
N°1 - Exhaust pipe Ø 80 (9)
Maximum usable lengths
(including intake terminal with grill and two 90° bends)
NON-INSULATED PIPE
INSULATED PIPE
Drain (metres)
Intake (metres)
Drain (metres)
Intake (metres)
1
36.0*
6
29.5*
2
34.5*
7
28.0*
3
33.0*
8
26.5*
4
32.0*
9
25.5*
5
30.5*
10
24.0*
* The air intake pipe can be increased to 2.5 metres if the exhaust bend
is eliminated, 2 metres if the air intake bend is eliminated, 4.5 metres
eliminating both bends.
11
22.5*
12
21.5*
Attention:
the boiler is designed to evacuate
the combustion products up to a maximum
extension of 27 linear metres from the exhaust,
with 1 m plus 90° bend at the intake. If the
installation requests a development of the flue
to the discharge that exceeds the recommended
12 m, due consideration must be given to the
formation of condensate that could take place
inside the pipe and Immergas insulated “Blue
Series” flue kits must be used.